TiS55+/TiS75+ Users Manual Measurement Menu Table 8 is a list of the options available in the Measurement menu. Table 8. Measurement Menu Option Menu Level/Span Emissivity Option Auto Manual Set Level/Span Custom Value Description Sets the Level/Span to adjust automatically or manually. With Level/Span set to Manual, changes the Level/Span. See Level/Span. Sets a custom emissivity value when a value from the standard emissivity table is not appropriate for the measurement. See Emissivity Adjustment. Select an emissivity value from a list of common materials. Use the scroll bar to see all of the options. See Emissivity Adjustment. Changes the background temperature to compensate for reflected background temperature. Background Transmissivity Very hot objects or very cold objects can affect the apparent temperature and measurement accuracy of the target, especially when surface emissivity is low. Adjust the reflected background temperature to improve the accuracy of the measurement. Changes the values used to calculate the temperature based on the transmission percentage of the infrared-transparent window (IR window). See Transmissivity. 12 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

TiS55+/TiS75+
Users Manual
12
Measurement Menu
Table 8
is a list of the options available in the Measurement menu.
Table 8. Measurement Menu
Option Menu
Option
Description
Level/Span
Auto
Sets the Level/Span to adjust automatically or
manually.
Manual
Set Level/Span
With Level/Span set to
Manual
, changes the
Level/Span. See
Level/Span
.
Emissivity
Custom Value
Sets a custom emissivity value when a value
from the standard emissivity table is not
appropriate for the measurement. See
Emissivity Adjustment
.
<options>
Select an emissivity value from a list of common
materials. Use the scroll bar to see all of the
options. See
Emissivity Adjustment
.
Background
<options>
Changes the background temperature to
compensate for reflected background
temperature.
Very hot objects or very cold objects can affect
the apparent temperature and measurement
accuracy of the target, especially when surface
emissivity is low. Adjust the reflected
background temperature to improve the
accuracy of the measurement.
Transmissivity
<options>
Changes the values used to calculate the
temperature based on the transmission
percentage of the infrared-transparent window
(IR window). See
Transmissivity
.