Frigidaire FAK085R7V Installation Instructions (All Languages) - Page 5
Level platform assembly from side-to-side. - instalation
![]() |
UPC - 012505272028
View all Frigidaire FAK085R7V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
4. Peel off protective backing from track seal. Apply seal to room side of window track. Center of seal strip should coincide with the line marked in Step 2. The two screw holes drilled in Step 3 should be directly above seal strip in the inner track. Apply track seal to window side of track. 5. Securely attach a siding-protection board to side of house. NOTE: Siding-protection board should be long enough to span 2 wall studs. Inside wall of house Siding-protection board 6. Place platform assembly, with platform tab against inside of window track, and attach it to window jamb. Use appropriate length screws (Items 9-11 in Preparing For Installation). 7. Adjust platform assembly so that outside edge is 3/16-inch lower than inside edge, as shown right. This ensures proper water drainage from the air conditioner. 8. Level platform assembly from side-to-side. Also, make sure window track is level. Use leveling shims as necessary to ensure unit is level from sideto-side. 9. Measure height of window opening from top of platform assembly as shown right. Subtract 20-5/8 inches. Mark this measurement on plastic window panel, along the longer side. (continued) Put platform tab against inside of track. Outside edge is 3/16-inch lower than inside. Measure distance and subtract 20 /5 8 inches. 5
![](/manual_guide/products/frigidaire-fak085r7v-installation-instructions-languages-a6a41a5/5.png)