Frigidaire FASE7021NW Installation Instructions (All Languages) - Page 10

Clearance requirements, continued

Page 10 highlights

INSTALLATION REQUIREMENTS Clearance requirements, continued Installation in a Recess or Closet 1 A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors. 2 No other fuel burning appliance shall be installed in the same closet as the gas dryer. 3 Your dryer needs the space around it for proper ventilation. DO NOT install your dryer in a closet with a solid door. 4 Closet door ventilation required: A minimum of 120 square inches (774.2 cm²) of opening, equally divided at the top and bottom of the door, is required. Openings should be located 3 inches (7.6 cm) from bottom and top of door. Openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable. MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR TOP FRONT Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a UnderCounter 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a Closet 0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.54 cm) * Dryer must be vented straight back to achieve 0" (0 cm) rear installation. 0" (0cm) 0" (0cm) 3" (7.6cm) 60 sq. in. (387.1cm²) 1" (2.54cm) 0" (0cm) 3" (7.6cm) closet door 60 sq. in. (387.1cm²) 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

10
INSTALLATION REQUIREMENTS
Clearance requirements, continued
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
TOP
FRONT
Alcove
0” (0 cm) 0” (0 cm)* 0” (0 cm)
n/a
Under-
Counter
0” (0 cm) 0” (0 cm)* 0” (0 cm)
n/a
Closet
0” (0 cm) 0” (0 cm)* 0” (0 cm)
1” (2.54 cm)
0”
(0cm)
0”
(0cm)
1”
(2.54cm)
0”
(0cm)
Dryer must be vented straight back to achieve
*
0” (0 cm) rear installation.
60 sq. in.
(387.1cm²)
3”
(7.6cm)
60 sq. in.
(387.1cm²)
3”
(7.6cm)
closet door
Installation in a Recess or Closet
1
A dryer installed in a bedroom, bathroom, recess or
closet, MUST be exhausted outdoors.
2
No other fuel burning appliance shall be installed in
the same closet as the gas dryer.
3
Your dryer needs the space around it for proper
ventilation.
DO NOT install your dryer in a closet with a solid door.
4
Closet door ventilation required: A minimum
of 120 square inches (774.2 cm²) of opening,
equally divided at the top and bottom of the
door, is required. Openings should be located 3
inches (7.6 cm) from bottom and top of door.
Openings are required to be unobstructed when a
door is installed. A louvered door with equivalent
air openings for the full length of the door is
acceptable.