Frigidaire FFHP124WS1 Installation Instructions - Page 12
Attention
![]() |
View all Frigidaire FFHP124WS1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. 4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side to side, up and down to check if it is hooked securely. Cushioning material Piping and wrapping 1. Bundle the tubing, connecting cable, and drain hose with tape securely and evenly as shown in the sideward figure. 2. Because the condensed water from rear of the indoor unit is gathered in ponding box and is piped out of room, do not put anything else in the box. Indoor unit Cable connection Drain hose Ponding box Pipe room Connective pipe Wrapping belt Attention!! 1. Connect the indoor unit first, then the outdoor unit. 2. Be careful not to let the drain hose slack. 3. Both of the auxiliary piping should be heat insulated. 4. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side may cause drain pan to overflow inside the unit. 5. Never intercross nor intertwist the power wire with any other wiring. 6. Run the drain hose sloped downward to drain out the condensed water smoothly. 11 Indoor unit installation
![](/manual_guide/products/frigidaire-ffhp124cs1-installation-instructions-84371c7/12.png)