Frigidaire FHWC3625MW Use and Care Manual - Page 9

Prepare The Location

Page 9 highlights

PREPARE THE LOCATION To wire through top: .Mark a line distance (A) from the right of the centerline on the underside of the cabinet. Mark the point on this line that is 7⁄8" (2.2 cm) from back wall. Drill a 1¼" (3.2 cm) diameter hole (B) through the cab net at this point. hood model 30" & 36" models Dim A 8³⁄8" (21.3 cm) A B 7⁄8" (2.2 cm) from wall, not cabinet frame Centerline To wire through wall: 1.Mark a line distance (A) from the right of the centerline on the underside of the wall. Mark the point on this line that is 7⁄8" (2.2 cm) from the underside of the cabinet. Drill a 1¼" (3.2 cm) diameter hole (B) through the rear wall at this point. hood Dim model A B 30" & 36" 8³⁄8" models (21.3 cm) 7⁄8" A (2.2 cm) A Centerline VENTING Choose venting exhaust discharge from the various options listed - Style 1 - 4 that follows: Style 1 - Recirculating Hood version For this installation, go to "Install Range Hood (recirculating version)" on page 11. Style 2 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm) Rectangular Vent System Roof Venting To make a 4" x 10½" (10.16 cm x 26.7 cm) rectangular cutout on the underside of cabinet top and bottom: 1.Mark lines ½" (1.3 cm) and 4¾" (12.1 cm) from the back wall on the centerline of the underside of cabinet. .Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the underside of cabinet. .Use saber or keyhole saw to cut a rectangular opening for vent. 4.Repeat steps 1-3 for the underside of the top of the cabinet. Centerline Cabinet cutouts *1/2 (1.3 cm) *43/4 51/4 (12.1 cm) (13.3 cm) 51/4 (13.3 cm) *From wall, not cabinet frame Wall Venting To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the wall: 1.Make 2 lines by measuring 3⁄8" (0.9 cm) and 37⁄8" (9.8 cm) down from underside of cabinet and mark on the centerline on the back wall. .Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the wall. .Use saber or keyhole saw to cut a rectangular opening in the wall for the vent. Cabinet front Centerline 3/8" (0.9 cm) 37/8" (9.8 cm) 51/4" 51/4" (13.3 cm) (13.3 cm) 

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

9
To wire through top:
Mark a line distance (A) from the right of the
centerline on the underside of the cabinet. Mark the
point on this line that is
7
8
” (2.2 cm) from back wall.
Drill a 1¼” (3.2 cm) diameter hole (B) through the cab
net at this point.
To wire through wall:
Mark a line distance (A) from the right of the
centerline on the underside of the wall. Mark the point
on this line that is
7
8
” (2.2 cm) from the underside of
the cabinet. Drill a 1¼” (3.2 cm) diameter hole (B)
through the rear wall at this point.
VENTING
Choose venting exhaust discharge from the various
options listed - Style 1 - 4 that follows:
Style 1 - Recirculating Hood version
For this installation, go to “Install Range Hood
(recirculating version)” on page 11.
±.
1.
A
Centerline
7
8
” (2.2 cm)
from wall,
not cabinet frame
B
A
A Centerline
7
8
(2.2 cm)
B
Style 2 - Cut Openings for 3¼” x 10” (8.3 cm x
±³.4 cm) Rectangular Vent System
Roof Venting
To make a 4” x 10½” (10.16 cm x 26.7 cm) rectangular
cutout on the underside of cabinet top and bottom:
Mark lines ½” (1.3 cm) and 4¾” (12.1 cm) from the
back wall on the centerline of the underside of cabinet.
Mark lines 5¼” (13.3 cm) to the right and left of the
centerline on the underside of cabinet.
Use saber or keyhole saw to cut a rectangular opening
for vent.
Repeat steps 1-3 for the underside of the top of the
cabinet.
Wall Venting
To make a 3½” x 10½” (8.9 cm x 26.7 cm) rectangle in
the wall:
Make 2 lines by measuring
3
8
” (0.9 cm) and 3
7
8
(9.8 cm) down from underside of cabinet and mark on
the centerline on the back wall.
Mark lines 5¼” (13.3 cm) to the right and left of the
centerline on the wall.
Use saber or keyhole saw to cut a rectangular opening
in the wall for the vent.
1.
±.
².
4.
1.
±.
².
Cabinet cutouts
*From wall, not cabinet frame
*
1
/
2
(1.3 cm)
5
1
/
4
(13.3 cm)
5
1
/
4
(13.3 cm)
*4
3
/
4
(12.1 cm)
Cabinet
front
Centerline
5
1
/
4
(13.3 cm)
3
7
/
8
(9.8 cm)
3
/
8
(0.9 cm)
5
1
/
4
(13.3 cm)
Centerline
PREPARE THE LOCATION
hood
model
Dim
A
30” & 36”
models
8³⁄
8
(21.3 cm)
hood
model
Dim
A
30” & 36”
models
8³⁄
8
(21.3 cm)