Error code E11 E13 E14 E21 E23 E24 E31 E35 E41 E42 E43 E44 E45 E46 E47 E48 E52 E55 E56 E57 E58 E59 E5A E5B E5C E5D E5E E5F E67 E75 E76 E95 EB1 EB2 Error code chart Fault condition Fill time too long. Water leak in tub or air leak in air bell. Reed switch. Water not pumping out fast enough. Drain pump relay on control board failed. Drain pump relay on control board failed. Better models. Pressure sensor not communicating with control board. Better models. Pressure sensor indicates water overfill. Control board thinks the door switch is open. Door remains locked after cycle is completed. Control board problem. Control board problem. Control board problem. Control board problem. Board thinks the door PTC circuit is open in spin. Board thinks the door PTC circuit is closed. Bad signal from tacho generator. Motor overheating. High motor current. High current on inverter. High current on motor phase. No tacho signal for 3 seconds. High temperature on heat sink. High temperature on heat sink. High temperature on heat sink. Communication problem. Communication problem. Communication problem. Input voltage on microprocessor incorrect. Better models only. Water temperature sensor circuit. Better model only. NTC temperature for the cold water valve over the limits. Communication error. Incoming power frequency out of limits. Incoming line voltage above 130 VAC. EB3 Incoming line voltage below 90 VAC. EF1 Clogged drain pump. EF2 To much soap. Check Refer to test (1). Refer to test (2). Refer to test (3). Refer to test (4). Replace control board. Replace control board. Refer to test (5). Refer to test (6). Refer to test (7). Refer to test (8). Replace the control board. Replace the control board. Replace the control board. Replace the control board. Refer to test (9) Refer to test (9) Refer to test (10) Refer to test (11) Refer to test (11) Refer to test (11) Refer to test (11) Refer to test (12) Replace the speed control board. Replace the speed control board. Replace the speed control board. Refer to test (13) Refer to test (13) Refer to test (13) Replace the control board. Refer to test (14) Hot and cold water hoses switched. Replace the control board. Refer to test (15) Check voltage at the outlet. If below 130 VAC, replace the control board. Check voltage at the outlet. If above 90 VAC, replace the control board. Unclog the drain pump. Advise customer to reduce the amount of soap they are using. 3 P/N 134408500

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

3
Error code chart
Error code
Fault condition
Check
E11
Fill time too long.
Refer to test (1).
E13
Water leak in tub or air leak in air bell.
Refer to test (2).
E14
Reed switch.
Refer to test (3).
E21
Water not pumping out fast enough.
Refer to test (4).
E23
Drain pump relay on control board failed.
Replace control board.
E24
Drain pump relay on control board failed.
Replace control board.
E31
Better models. Pressure sensor not communicating
Refer to test (5).
with control board.
E35
Better models. Pressure sensor indicates water overfill.
Refer to test (6).
E41
Control board thinks the door switch is open.
Refer to test (7).
E42
Door remains locked after cycle is completed.
Refer to test (8).
E43
Control board problem.
Replace the control board.
E44
Control board problem.
Replace the control board.
E45
Control board problem.
Replace the control board.
E46
Control board problem.
Replace the control board.
E47
Board thinks the door PTC circuit is open in spin.
Refer to test (9)
E48
Board thinks the door PTC circuit is closed.
Refer to test (9)
E52
Bad signal from tacho generator.
Refer to test (10)
E55
Motor overheating.
Refer to test (11)
E56
High motor current.
Refer to test (11)
E57
High current on inverter.
Refer to test (11)
E58
High current on motor phase.
Refer to test (11)
E59
No tacho signal for 3 seconds.
Refer to test (12)
E5A
High temperature on heat sink.
Replace the speed control
board.
E5B
High temperature on heat sink.
Replace the speed control
board.
E5C
High temperature on heat sink.
Replace the speed control
board.
E5D
Communication problem.
Refer to test (13)
E5E
Communication problem.
Refer to test (13)
E5F
Communication problem.
Refer to test (13)
E67
Input voltage on microprocessor incorrect.
Replace the control board.
E75
Better models only.
Water temperature sensor circuit.
Refer to test (14)
E76
Better model only.
NTC temperature for the cold water
Hot and cold water hoses
valve over the limits.
switched.
E95
Communication error.
Replace the control board.
EB1
Incoming power frequency out of limits.
Refer to test (15)
EB2
Incoming line voltage above 130 VAC.
Check voltage at the outlet. If
below 130 VAC, replace the
control board.
EB3
Incoming line voltage below 90 VAC.
Check voltage at the outlet. If
above 90 VAC, replace the
control board.
EF1
Clogged drain pump.
Unclog the drain pump.
EF2
To much soap.
Advise customer to reduce
the amount of soap they are
using.
P/N 134408500