Page 64 highlights
(4) Service clearance area The service clearance area, or the sides which must allow access to the IDD for installation or maintenance, is shown in Figures 4.11. [Surface P'] • Setting terminal • External operator panel connector • Spindle sync connector [Surface R] • Hole for mounting screw [Surface P] • Cable connection [Surface Q] • Hole for mounting screw Figure 4.11 Service clearance area (5) External magnetic field The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence of the external magnetic field. (6) Leak magnetic flux The IDD uses a high performance magnet to achieve a high speed seek. Therefore, a leak magnetic flux at surface of the IDD is large. Mount the IDD so that the leak magnetic flux does not affect to near equipment. (7) Others A hole or screw portion as shown in Figure 4.12 is used for adjusting air pressure balance between inside and outside the DE. Do not fill with a seal or label. Seals on the DE prevent the DE inside from the dust. Do not damage or peel off labels. C141-E064-03EN 4 - 11