Fujitsu MAN3367MC Manual/User Guide - Page 30
Function specifications, ANSI X3.131-1986, ANSI X3.131-1994 and CCS Rev. 4B - rpm
View all Fujitsu MAN3367MC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
2.1.2 Function specifications Table 2.1 shows the function specifications of the IDD. Table 2.1 Function specifications Item Formatted capacity/device (*1) Number of disks Number of heads Number of cylinders (*2) Formatted capacity/track (B) Number of rotations min-1 (rpm) Average latency time Seek time (*3) (Read/Write) Track to Track Average Full stroke Start/stop time Start time (*4) Stop time Recording mode External dimensions Height: Width: Depth: Weight (max) Power consumption (*5) Fast 5 SCSI MAN3735 series 73.49 GB 4 8 29,902 9.5 W Specification MAN3367 series 36.74 GB 2 4 29,950 230,400 to 377,344 10,025±0.2% 2.99 msec 0.4 ms/0.6 ms 4.5 ms/5.0 ms 11.0 ms/12.0 ms 30 s typ. (60 s max.) 30 s typ. 32/34 MEEPRML 25.4 mm 101.6 mm 146.0 mm 0.75 kg 7.5 W Cable length: 6 m max MAN3184 series 18.37 GB 1 2 30,050 7.0 W Single- Fast 10 SCSI Inter- Ended face Fast 20 SCSI Cable length: 3 m max Cable length: 3 m max (*6) Cable length: 1.5 m max (*7) LVD Cable length: 25 m max (*8) Cable length: 12 m max (*9) Data transfer rate (*10) Disk drive SCSI Synchronous mode 52.0 to 84.1 MB/s 160 MB/s max. Logical data block length (*11) 512 to 528 byte (Fixed length) SCSI command specification ANSI X3.131-1986, ANSI X3.131-1994 and CCS (Rev. 4B) conformity SPC-2 (T10/1236-D Rev 12), SBC (ANSI NCITS306-199x) command partial support Data buffer 8 MB FIFO ring buffer Acostic noise (Ready) 3.9 bels 3.6 bels 3.6 bels 2 - 2 C141-E128-01EN