Selecting Zone Detection Selecting One-Zone or Two-Zone Detection Position the jumper as shown to select one or two zone detection. Zone Patterns Top View Standard Mfg.0128 Two Zone (4 pulses) SENTROL REMOVE FOR TEST 6155XT-N One Zone (2 pulses) Listed U 3 2 K 9 L Intrusion detection unit  burglary 7-16VDC, 10mA (max) NC COM TMP TMP + - 2-Zone Detection 1-Zone Detection 40' 12.2m 30' 9.1m 20' 6.1m 10' 3.0m Each zone is made up of two beams, one positive and one negative. With one zone selected, the unit detects the intruder moving across one zone. With two zones selected, the unit detects the intruder moving across two zones. Two-zone detection is recommended to reduce chances of false alarms. 2 Beams +- 2 Beams +- 2 Beams +- 0 0 10' 3.0m 20' 6.1m 30' 9.1m 40' 12.2m Side View 6'10" 2.1m 30° 4° 15° Floor Line Vertical Barrier Top View One-Zone Detection Two-Zone Detection Wiring Strip back the outer jacket on the wiring cable. This will allow wires to flex in the case. Make sure the cable is slack in the wall to avoid stressing the wires at their connections. NC COM TMP TMP + - 6155XT Model POWER-IN: 7 TO 16 VDC 0' 6° Side View 6'10" 2.1m 3° 6' 0.9m 1.8m 19' 5.8m 29' 8.8m 34' 40' 10.4m 12.2m NC COM T/NO TMP + - 6157XT Model POWER-IN: 7 TO 16 VDC Note When mounting the unit at 6'10"(2.1m) (for typical coverage), align arrows on the ball joint shoe with zeroes on the ball joint. This is the 0° setting. For every 1' (0.3m) above the typical mounting height, tilt the shoe down 1°.For example, for 7'10" (2.4m), tilt down 1°; for 8'10" (2.7m), tilt down 2°; etc. 6150 Extended Temperature Series SharpShooter PIR 3

  • 1
  • 2
  • 3
  • 4

6150 Extended Temperature Series SharpShooter PIR
3
Selecting Zone Detection
Selecting One-Zone or Two-Zone Detection
Position the jumper as shown to select one or two zone detection±
Each zone is made up of two beams, one positive and one
negative± With one zone selected, the unit detects the intruder
moving across
one zone
±
With two zones selected, the unit detects the intruder moving
across
two zones
± Two-zone detection is recommended to reduce
chances of false alarms±
-
2 Beams
2 Beams
+
-
+
Two-Zone Detection
One-Zone Detection
2 Beams
-
+
Note
When mounting the unit at 6'10"(2±1m) (for typical coverage),
align arrows on the ball joint shoe with zeroes on the ball joint±
This is the 0° setting± For every 1' (0±3m) above the typical
mounting height, tilt the shoe down 1°±For example, for 7'10"
(2±4m), tilt down 1°; for
8'10" (2±7m), tilt down 2°; etc±
NC COM
TMP
TMP
+
NC COM
T/NO
TMP
+
POWER-IN:
7 TO 16 VDC
6155XT
Model
POWER-IN:
7 TO 16 VDC
6157XT
Model
Wiring
Strip back the outer jacket on the wiring cable± This will allow
wires to flex in the case± Make sure the cable is slack in the wall to
avoid stressing the wires at their connections±
Two Zone
(4 pulses)
One Zone
(2 pulses)
NC
COM
TMP TMP
+
-
U
L
6155XT-N
Mfg±0128
SENTROL
REMOVE FOR TEST
Listed
32K9
I
ntrusion detection unit
burglary
7-16VDC, 10mA (max)
2-Zone Detection
1-Zone Detection
Zone Patterns
Standard
Top View
40'
12±2m
30'
9±1m
20'
6±1m
10'
3±0m
0
Side View
6'10"
2±1m
0
10'
20'
30'
40'
3±0m
6±1m
9±1m
12±2m
30°
15°
Floor Line
Top View
Side View
6'
19'
29'
34'
40'
0±9m
1±8m
5±8m
8±8m
10±4m
12±2m
0'
6'10"
2±1m
Vertical Barrier