GE 6155 Installation Instructions - Page 4

Specifications, Product Ordering, Completing the Installation, Troubleshooting with Test Mode

Page 4 highlights

Completing the Installation 1. Reassemble the unit. 2. Seal the openings with RTV compound. 3. Perform a walktest to confirm correct operation. 4. Slide the LED cover up to hide the LED, if desired. Troubleshooting with Test Mode The unit has a test mode to: • Verify the exact location of the beams • Determine the unit’s false alarm safety margin To access the test mode, remove the zone-selection jumper. Removal of the jumper doubles the sensitivity (gain) of the unit and sets the output and LED to alarm as you enter each beam. Remember, there are two beams in each zone. Mfg.0128 Two Zone (4 pulses) SENTROL REMOVE FOR TEST 6155XT-N One Zone (2 pulses) Listed U 3 2 K 9 L Intrusion detection unit  burglary 7-16VDC, 10mA (max) NC COM TMP TMP + - For further assistance, call Interlogix at 1-800-648-7424. Specifications Housing material Flame retardant ABS Voltage 7 to 16 VDC Current 8 mA typical, 10 mA max Maximum loop rating 16 VDC, 50 mA Alarm output Fail safe contacts with 10 ohms in series, 6155XT - Form A, Closed loop (NC) 6157XT - Form C, Closed and Open loop (SPDT) Alarm duration 2 to 5 seconds Cover tamper contacts Closed loop, rating: 50 mA Operating temperature 5° to 120°F (-15° to 50°C) Humidity 10 to 90% non-condensing RFI immunity Greater than 10V/m from 0 to 1000MHz Static/lighting immunity 2.5 KV, 2 joules max energy impulse, 1 msec rise / 50 msec decay Pulse count Bi-directional, 1 event (2 pulses) or 2 events (4 pulses) Range (lenses) Standard XT 40' (12.2m) x 90° Vertical Barrier XT ± 1.25°C Minimum temperature differential Standard XT ± 1° C Vertical barrier ± 1.25° C Standard swivel bracket ±10° left/right, 10° up, 15° down LED indicator Walktest Dimensions Width 2.9" (7.3cm) Height 3.7" (9.4cm) Depth 2.4" (6.1cm) Color Off-White 1.9" 4.8cm Top View 2.2" 5.5cm Front View Side View 2.9" 7.3cm 2.4" 6.1cm 45° 3.7" 9.4cm Product Ordering Model 6155XT 6157XT Loop Type Closed Closed, Open 4 Electrical Configuration N.C. SPDT (N.C. and N.O.) Listing UL UL ©2001 Interlogix, Inc. Interlogix, Caddx, ESL, ITI and Sentrol are trademarks of Interlogix,Inc. All other trademarks are properties of their respective owners. 10751 Rev. C 07/01 6150 Extended Temperature Series SharpShooter PIR

  • 1
  • 2
  • 3
  • 4

6150 Extended Temperature Series SharpShooter PIR
4
Specifications
Housing material
Flame retardant ABS
Voltage
7 to 16 VDC
Current
8 mA typical, 10 mA max
Maximum loop rating
16 VDC, 50 mA
Alarm output
Fail safe contacts with 10 ohms in series,
6155XT - Form A, Closed loop (NC)
6157XT - Form C, Closed and Open loop (SPDT)
Alarm duration
2 to 5 seconds
Cover tamper contacts
Closed loop, rating: 50 mA
Operating temperature
5° to 120°F (-15° to 50°C)
Humidity
10 to 90%
non-condensing
RFI immunity
Greater than 10V/m from 0 to 1000MHz
Static/lighting immunity
2±5 KV, 2 joules max energy impulse,
1 msec rise / 50 msec decay
Pulse count
Bi-directional, 1 event (2 pulses)
or 2 events (4 pulses)
Range (lenses)
Standard XT 40' (12±2m) x 90°
Vertical Barrier XT
² 1±25°C
Minimum temperature
differential
Standard XT ² 1° C
Vertical barrier
² 1±25° C
Standard swivel bracket
²10° left/right, 10° up, 15° down
LED indicator
Walktest
Dimensions
Width 2±9" (7±3cm)
Height 3±7" (9±4cm)
Depth 2±4" (6±1cm)
Color
Off-White
Product Ordering
Model
Loop Type
Electrical Configuration
Listing
6155XT
Closed
N±C±
UL
6157XT
Closed, Open
SPDT (N±C± and N±O±)
UL
Completing the Installation
1± Reassemble the unit±
2± Seal the openings with RTV compound±
3± Perform a walktest to confirm correct operation±
4± Slide the LED cover up to hide the LED, if desired±
Troubleshooting with Test Mode
The unit has a test mode to:
µ Verify the exact location of the beams
µ Determine the unit´s false alarm safety margin
To access the test mode, remove the zone-selection jumper±
Removal of the jumper doubles the sensitivity (gain) of the unit
and sets the output and LED to alarm as you enter each beam±
Remember, there are two beams in each zone±
For further assistance, call Interlogix at
1-800-648-7424±
Two Zone
(4 pulses)
One Zone
(2 pulses)
NC
COM
TMP TMP
+
-
U
L
6155XT-N
Mfg±0128
SENTROL
REMOVE FOR TEST
Listed
32K9
I
ntrusion detection unit
burglary
7-16VDC, 10mA (max)
Front View
Side View
2±9"
7±3cm
3±7"
9±4cm
2±4"
6±1cm
45°
Top View
2±2"
5±5cm
1±9"
4±8cm
10751 Rev± C 07/01
©2001 Interlogix, Inc.
Interlogix, Caddx, ESL, ITI and Sentrol are trademarks of Interlogix,Inc.
All other trademarks are properties of their respective owners.