Installation, Instructions, Connect the Range to the Gas Supply, DO NOT USE

Page 45 highlights

Safety Instructions Operating Instructions Read these instructions completely and carefully. Connect the Range to the Gas Supply Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hookup has been completed. Don't forget to relight the pilot on other gas appliances when you turn the gas back on. Because hard piping restricts movement of the range, the use of a CSA International-certified flexible metal appliance connector is recommended unless local codes require a hard-piped connection. Never use an old connector when installing a new range. If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made. To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads. Install a manual gas line shut-off valve in the gas line in an easily accessed location outside of the range. Make sure everyone operating the range knows where and how to shut off the gas supply to the range. Install male 1/2″ flare union adapter to the 1/2″ NPT internal thread elbow at inlet of regulator. Use a backup wrench on the regulator fitting to avoid damage. When installing the range from the front, remove the 90° elbow for easier installation. Install male 1/2″ or 3/4″ flare union adapter to the NPT internal thread of the manual shut-off valve, taking care to backup the shut-off valve to keep it from turning. Connect flexible metal appliance connector to the adapter on the range. Position range to permit connection at the shut-off valve. When all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system. CAUTION : DO NOT USE A FLAME TO CHECK FOR GAS LEAKS. When using test pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut-off valve from the gas supply piping. When using test pressures of 1/2 psig or less to test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve. *Teflon: Registered trademark of DuPont Installation Instructions Flexible Connector Hookup Rigid Pipe Hookup Options Troubleshooting Tips Consumer Support Pressure regulator Adapter Installer: Inform the consumer of the location of the gas shut-off valve. 1/2″ or 3/4″ Gas pipe Gas Flow into Range 45° Elbow Gas Flow into Range 90° Elbow Flex connector (6 ft. max.) Adapter Gas shut-off valve Nipple Black iron pipe Pressure regulator Union Installer: Inform the consumer of the location of the gas shut-off valve. Alternate Hookup Adapter Union Nipple Gas shut-off valve 1/2″ or 3/4″ Gas pipe 90° Elbow Nipple Gas shut-off valve 90° Elbow Nipple Quick connect or union Nipple Pressure regulator 90° Elbow 1/2″ or 3/4″ Gas pipe 90° Elbow Installer: Inform the consumer of the location of the gas shut-off valve. Adapter Gas Flow into Range 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

45
Read these instructions completely and carefully.
Connect the Range to the Gas Supply
Because hard piping restricts movement of the
range, the use of a CSA International-certified
flexible metal appliance connector is recommended
unless local codes require a hard-piped connection.
Never use an old connector when installing a
new range. If the hard piping method is used, you
must carefully align the pipe; the range cannot be
moved after the connection is made.
To prevent gas leaks, put pipe joint compound on,
or wrap pipe thread tape with Teflon* around, all
male (external) pipe threads.
Install a manual gas line shut-off valve in the
gas line in an easily accessed location outside
of the range. Make sure everyone operating
the range knows where and how to shut off
the gas supply to the range.
Install male 1/2
flare union adapter to
the 1/2
NPT internal thread elbow at inlet
of regulator. Use a backup wrench on the
regulator fitting to avoid damage.
When installing the range from the front,
remove the 90° elbow for easier installation.
Install male 1/2
or 3/4
flare union adapter to
the NPT internal thread of the manual shut-off
valve, taking care to backup the shut-off valve
to keep it from turning.
Connect flexible metal appliance connector
to the adapter on the range. Position range
to permit connection at the shut-off valve.
When all connections have been made, make
sure all range controls are in the off position
and turn on the main gas supply valve.
Use a liquid leak detector at all joints and
connections to check for leaks in the system.
When using test pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping. When
using test pressures of 1/2 psig or less to test the
gas supply system, simply isolate the range from
the gas supply system by closing the individual
shut-off valve.
*Teflon: Registered trademark of DuPont
CAUTION:
DO NOT USE A
FLAME TO CHECK FOR GAS LEAKS.
Shut off the main gas supply valve before disconnecting the old range and leave it off
until the new hookup has been completed. Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.
Flexible Connector Hookup
Rigid Pipe Hookup Options
Pressure
regulator
Gas Flow into Range
Flex
connector
(6 ft. max.)
Adapter
Installer: Inform
the consumer of
the location of the
gas shut-off valve.
1/2
or 3/4
Gas pipe
Adapter
Gas
shut-off
valve
Pressure
regulator
45° Elbow
Nipple
Union
90° Elbow
Black
iron pipe
Union
Nipple
Gas
shut-off
valve
1/2
or 3/4
Gas pipe
Gas Flow into Range
Installer: Inform the consumer of the
location of the gas shut-off valve.
Gas Flow into Range
Gas
shut-off
valve
1/2
or 3/4
Gas pipe
Pressure
regulator
Nipple
90° Elbow
90° Elbow
Adapter
Adapter
90° Elbow
Quick connect
or union
Installer: Inform the consumer of the
location of the gas shut-off valve.
Alternate Hookup
Nipple
Nipple
90°
Elbow
Consumer Support
Operating Instructions
Safety Instructions
Installation
Instructions
Troubleshooting Tips