Installation Instructions CONNECTING DRYER POWER CORD (cont.) D For 3-wire Connection ONLY: Be sure the dryer's green ground wire is connected to green ground screw on cabinet rear. CONNECTING DRYER POWER CORD (cont.) E For 3-wire and 4-wire Connection: Connect the neutral (center line on 3-wire, white line on 4-wire) line to the center of terminal block. Connect Center Screw Ground Wire (3-Wire Connection Shown) For 4-wire Connection ONLY: Remove the dryer's ground wire from behind the green ground screw and connect it to the center screw of the terminal block. Attach ground wire of power cord to the cabinet with the green ground screw. (3-Wire Connection Shown) F For 3-wire and 4-wire Connection: Tighten all terminal block screws completely. Power Cord Ground Wire (3-Wire Connection Shown) G For 3-wire and 4-wire Connection: Reinstall the terminal block access cover. IMPORTANT: Do not leave the access cover off. (4-Wire Connection Shown) 27 (3-Wire Connection Shown)