Installation Instructions - pedestal
UPC - 084691201229
View all GE GFWH2405LMS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Installation Instructions LOCATION OF YOUR WASHER Do Not Install the Washer: 1. In an area exposed to dripping water or outside weather conditions. The ambient temperature should never be below 60°F (15.6°C) for proper wash3e4"r(86.36 cm) operation. 2. In an area where it will come in contact with curtains or drapes. 3. O n carpet. The floor MUST be a hard surface with a maximum slope of 1/2″ per foot (1.27 cm per 30 cm). To make sure the washer does not vibrate or move, you may have to reinforce the floor. NOTE: If floor is in poor condition, use 3/4″ impregnated plywood sheet solidly attached to the existing floor covering. IMPORTANT: Minimum Installation Clearances • When installed in alcove: Sides, Rear, Top = 0″ (0 cm) • When installed in closet: Sides, Rear, Top = 0″ (0 cm), Front = 1″ (2.54 cm) • Closet door ventilation openings required: 2 louvers each 60 square in. (387 cm2), located 3″ (7.6 cm) from top and bottom of door 39" (99.06 cm) 39.8" (101.1 cm) 0.83" (2.1 cm) ROUGH-IN DIMENSIONS FRONT 27" (68.58 cm) SIDE 34" (86.36 cm) 39.8" (101.1 cm) 27" (68.58 0.83" (2.1 cm) 39" (99.06 cm) 39.8" (101.1 cm) *NOTE: With Washer Legs: 40.5" (102.5 cm) (0.75" adjustability) With Pedestal: 53.75" (136.6 cm) (0.75" adjustability) Stacked: 82.75" (209.8 cm) 15