Safety Instructions Installation Instructions Operating Instructions Care and cleaning of the water heater. Care and Cleaning Draining the Water Heater ! CAUTION: Shut off gas to the water heater at the gas control (thermostat) gas cock or manual shut-off valve before draining water. ! DANGER: Before manually operating the temperature and pressure relief valve, make certain no one will be exposed to the hot water released by the valve. The water drained from the tank may be hot enough to present a scald hazard and should be directed to a suitable drain to prevent injury or damage. In order to drain the water heater, turn off the cold water supply. Open a hot water faucet or lift the handle on the relief valve to admit air to the tank. Attach a garden hose to the drain valve on the water heater and direct the stream of water to a drain. Open the valve. ! DANGER: Before manually operating the relief valve, make certain no one will be exposed to the danger of the hot water released by the valve. The water may be hot enough to create a scald hazard. The water should be released into a suitable drain to prevent injury or property damage. ! DANGER: Hotter water increases the potential for Hot Water Scalds. ! DANGER: Failure to perform the recommended Routine Preventative Maintenance can harm the proper operation of this water heater, which can cause carbon monoxide dangers, excessive hot water temperatures and other potentially hazardous conditions Routine Preventative Maintenance Properly maintained, your water heater will provide years of dependable trouble-free Because accumulated solids can prevent the gas control (thermostat) sensors from service. accurately reading the water temperature, It is recommended that a periodic inspection of the gas control (thermostat), burner, relief valve, internal flue-way and venting system should be made by service personnel qualified in gas appliance repair. the water at the fixture can be hotter than the gas control (thermostat) dial setting. It is suggested that a few quarts of water be drained from the water heater's tank every month to clean the tank of these deposits. It is suggested that a routine preventative Rapid closing of faucets or solenoid valves in maintenance program be established and automatic water using appliances can cause followed by the user. a banging noise heard in a water pipe. At least once a year, lift and release the lever handle on the temperature pressure relief valve, located near the top of the water heater, to make certain the valve operates freely. Allow several gallons to flush through the discharge line to an open drain. Strategically located risers in the water pipe system or water hammer arresting devices can be used to minimize the problem. The anode rod should be removed from the water heater's tank annually for inspection and replaced when more than 6" of core NOTICE: If the temperature and wire is exposed at either end of the rod. pressure relief valve on the hot water heater discharges periodically, this may be due to thermal expansion in a closed water system. Contact the water supplier or your plumbing contractor on how to correct this. DO NOT plug the relief Make sure the cold water supply is turned off before removing anode rod. This water heater incorporates a combustion shut off device that shuts the operation of the water heater down valve outlet. if undesirable combustion conditions occur. A water heater's tank can act as a setling basin for solids suspended in the water. It is therefore not uncommon for hard water deposits to accumulate in the bottom of the tank. If allowed to accumulate, these solids Such as the presence of flammable vapors or blockage of the combustion air inlet openings. Please contact a Qualified Service Technician if this occurs. can cover the gas control (thermostat) sensors, causing the sensors to operate erratically. ! DANGER: Combustible materials, such as clothing, cleaning materials, or flammable liquids, etc., must not be placed against or next to the water heater. Housekeeping Visually inspect pilot burner and relight if necessary. To ensure sufficient ventilation and combustion air supply, proper clearances must be maintained. When installed in a closet, DO NOT block or obstruct any of the combustion air inlet openings located around the perimeter of the water heater. A minimum of 1" is required between these combustion air inlet openings and any obstruction. 19 Troubleshooting Tips Customer Service

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

19
Safety Instructions
Installation Instructions
Operating Instructions
Care and Cleaning
Troubleshooting Tips
Customer Service
Care and cleaning of the water heater.
Draining the Water Heater
CAUTION:
Shut off gas to the water
heater at the gas control (thermostat)
gas cock or manual shut-off valve
before draining water.
DANGER:
Before manually operating
the temperature and pressure relief
valve, make certain no one will be
exposed to the hot water released by the
valve. The water drained from the tank
may be hot enough to present a scald
hazard and should be directed to a
suitable drain to prevent injury or
damage.
In order to drain the water heater, turn off
the cold water supply. Open a hot water
faucet or lift the handle on the relief valve
to admit air to the tank.
Attach a garden hose to the drain
valve on the water heater and direct
the stream of water to a drain. Open
the valve.
!
!
DANGER:
Combustible
materials, such as clothing,
cleaning materials, or
flammable liquids, etc.,
must not be placed against
or next to the water heater.
!
Housekeeping
Visually inspect pilot burner and relight if
necessary.
To ensure sufficient ventilation and
combustion air supply, proper clearances
must be maintained.
When installed in a closet, DO NOT
block or obstruct any of the combustion
air inlet openings located around the
perimeter of the water heater. A
minimum of 1” is required between
these combustion air inlet openings and
any obstruction.
DANGER:
Before
manually operating the
relief valve, make certain
no one will be exposed to
the danger of the hot water
released by the valve. The
water may be hot enough
to create a scald hazard.
The water should be
released into a suitable
drain to prevent injury or
property damage.
DANGER:
Hotter water
increases the potential for
Hot Water Scalds.
DANGER:
Failure to
perform the recommended
Routine Preventative
Maintenance can harm the
proper operation of this
water heater, which can
cause carbon monoxide
dangers, excessive hot
water temperatures and
other potentially hazardous
conditions
!
!
!
Routine Preventative Maintenance
Properly maintained, your water heater will
provide years of dependable trouble-free
service.
It is recommended that a periodic inspection
of the gas control (thermostat), burner,
relief valve, internal flue-way and venting
system should be made by service personnel
qualified in gas appliance repair.
It is suggested that a routine preventative
maintenance program be established and
followed by the user.
At least once a year, lift and release the
lever handle on the temperature pressure
relief valve, located near the top of the water
heater, to make certain the valve operates
freely. Allow several gallons to flush through
the discharge line to an open drain.
NOTICE:
If the temperature and
pressure relief valve on the hot water
heater discharges periodically, this may
be due to thermal expansion in a closed
water system. Contact the water supplier
or your plumbing contractor on how to
correct this. DO NOT plug the relief
valve outlet.
A water heater’s tank can act as a setling
basin for solids suspended in the water. It is
therefore not uncommon for hard water
deposits to accumulate in the bottom of the
tank. If allowed to accumulate, these solids
can cover the gas control (thermostat)
sensors, causing the sensors to operate
erratically.
Because accumulated solids can prevent the
gas control (thermostat) sensors from
accurately reading the water temperature,
the water at the fixture can be hotter than
the gas control (thermostat) dial setting. It
is suggested that a few quarts of water be
drained from the water heater’s tank every
month to clean the tank of these deposits.
Rapid closing of faucets or solenoid valves in
automatic water using appliances can cause
a banging noise heard in a water pipe.
Strategically located risers in the water pipe
system or water hammer arresting devices
can be used to minimize the problem.
The anode rod should be removed from the
water heater’s tank annually for inspection
and replaced when more than 6”
of core
wire is exposed at either end of the rod.
Make sure the cold water supply is turned
off before removing anode rod.
This water heater incorporates a
combustion shut off device that shuts
the operation of the water heater down
if undesirable combustion conditions occur.
Such as the presence of flammable vapors
or blockage of the combustion air inlet
openings. Please contact a Qualified