GE JGP940SEKSS Installation Instructions - Page 15
CHAnge CooKToP Burner, orifiCeS ConT. - lowes
UPC - 084691114437
View all GE JGP940SEKSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Installation Instructions 3 Change Cooktop Burner Orifices (CONT.) D Locate the LP/Propane orifices shipped inside the literature package. They will have a digit number and the letter "L" on the side. (Important: Save the orifices removed from the appliance for future use.) Each orifice will show a series of engraved marks, (i, II, III, X or none), located on the top. These marks denote the precise location of each orifice to the cooktop burner. I II III X I II III X 18,000 BTU/HR Burner (on some models) The 18,000 BTU/HR burner has two orifices with markings located in the sides only. (See rating plate on bottom of appliance). NOTE: The main orifice is located low in the center of the burner while the simmer orifice is located higher behind the center of the burner. Simmer orifice Main orifice Left Rear Model Orifice JGP328 II JGP330 II JGP933 III Left Front Orifice II II II Right Front Orifice II III X JGP940 III JGP945 III III X II Replace: With: Main 206X N ➔ 108X L Simmer 57N ➔ 34L E Install the LP/Propane orifices in their precise locations as noted in the illustrations above. F Return the natural gas orifices to the bracket and reattach the bracket and the instruction sheet to the pressure regulator using the screw removed previously. G Replace the burner bases, heads, caps and top grates. (Note: When re-attaching the burner bases to glass top units, tighten screws to a maximum of 10 in.-lbs torque.) 15