GE JGP963 Installation Instructions - Page 13

Installation Instructions, MAKING THE LP CONVERSION - installation manual

Page 13 highlights

Installation Instructions MAKING THE LP CONVERSION 1 SAFETY INFORMATION YOU SHOULD KNOW The pressure regulator and burner orifices are set for natural gas. To use Propane Gas, the regulator and burner orifices must be converted. The LP orifice spuds for the cooktop burners can be located in the literature package. CAUTION: The cooktop, as shipped from the factory, is set for use with natural gas. If you wish to use your cooktop with Liquefied Petroleum (Propane) gas, you must first replace the orifices and convert the pressure regulator. WARNING: This conversion must be performed by a qualified installer or gas supplier in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion. CAUTION: The following adjustments must be made before turning on the burner. Failure to do so could result in serious injury. Be sure pressure regulator has been converted as described in Step 2. 2 ADJUST YOUR COOKTOP FOR USE WITH LP GAS A Disconnect all electrical power, at the main circuit breaker or fuse box. B Shut off the gas supply to the cooktop by closing the manual shut-off valve. C Adjust the pressure regulator, by the following instructions: • Unscrew the cap. • Place your thumb against the flat side of the spring retainer and press down to remove the retainer. • Carefully look at the spring retainer to locate the NAT or LP position. Cap Gasket DOWN FOR OFF NAT NAT LP LP NAT NAT NAT. Position LP Spring Retainer LP L.P./Propane Position Pressure Regulator • Turn the spring retainer over so that LP is showing on the bottom. • Snap the retainer back into position. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

13
Installation Instructions
MAKING THE LP CONVERSION
SAFETY INFORMATION YOU
SHOULD KNOW
The pressure regulator and burner orifices
are set for natural gas. To use Propane Gas,
the regulator and burner orifices must be
converted. The LP orifice spuds for the
cooktop burners can be located in the
literature package.
CAUTION:
The cooktop, as shipped
from the factory, is set for use with natural
gas. If you wish to use your cooktop with
Liquefied Petroleum (Propane) gas, you must
first replace the orifices and convert the
pressure regulator.
WARNING:
This conversion must
be performed by a qualified installer or gas
supplier in accordance with the manufacturer’s
instructions and all codes and requirements
of the authority having jurisdiction. Failure
to follow instructions could result in serious
injury or property damage. The qualified
agency performing this work assumes
responsibility for the conversion.
CAUTION:
The following adjustments
must be made before turning on the burner.
Failure to do so could result in serious injury.
Be sure pressure regulator has been
converted as described in Step 2.
1
ADJUST YOUR COOKTOP FOR
USE WITH LP GAS
Disconnect all electrical power, at the
main circuit breaker or fuse box.
Shut off the gas supply to the cooktop
by closing the manual shut-off valve.
Adjust the pressure regulator, by the
following instructions:
Unscrew the cap.
Place your thumb against the flat side
of the spring retainer and press down
to remove the retainer.
Carefully look at the spring retainer to
locate the NAT or LP position.
Turn the spring retainer over so that
LP is showing on the bottom.
Snap the retainer back into position.
C
B
A
2
DOWN
FOR OFF
NAT
LP
LP
NAT
LP
NAT
NAT
LP
Gasket
Cap
Spring
Retainer
L.P./Propane
Position
NAT.
Position
Pressure Regulator