Installation Instructions INSTALLING THE COOKTOP 1 PROVIDE ADEQUATE GAS SUPPLY This cooktop is designed to operate on natural gas at 4″ of water column pressure. It is shipped from the factory set for natural gas. The convertible pressure regulator supplied with the unit must be connected in series with the manifold of the cooktop and must remain in series with the supply line regardless of whether natural or L.P. gas is being used. FOR PROPER OPERATION, THE MAXIMUM INLET PRESSURE TO THE REGULATOR MUST BE NO MORE THAN 14″ OF WATER COLUMN PRESSURE. For checking the regulator, the inlet pressure must be at least 1″ (or 3.4 KPA) greater than the regulator output setting. If the regulator is set for 4″ of water column pressure, the inlet pressure must be at least 5″. If the regulator is set for 10″, the inlet pressure must be at least 11″. The gas supply line to the cooktop should be 1/2″ or 3/4″ pipe. 2 INSTALL REGULATOR NEVER REUSE OLD CONNECTORS WHEN INSTALLING THIS COOKTOP. WARNING: Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use new flexible connectors when installing a gas appliance. Screw a section of pipe onto each end of the pressure regulator. Pressure Regulator To reduce the likelihood of gas leaks, apply teflon tape or a thread compound approved for use with LP or Natural gases to all threaded connections. 3 INSTALL REGULATOR ONTO BURNER BOX BOTTOM Screw the regulator and pipe connection into the burner box bottom. Make sure the top of the regulator is facing towards the cabinet front, easily accessible through the cabinet doors. Pressure Regulator Shut-Off Valve Electrical Outlet 12″ Below Countertop 4 COMPLETE CONNECTION WITH A COUPLING Install a coupling between the regulator and the shu-off valve to complete the connection. Pressure Regulator Coupling Shut-Off Valve Electrical Outlet 12″ Below Countertop 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

6
Installation Instructions
INSTALLING THE COOKTOP
PROVIDE ADEQUATE
GAS SUPPLY
This cooktop is designed to operate on
natural gas at 4
of water column pressure.
It is shipped from the factory set for natural
gas. The convertible pressure regulator
supplied with the unit must be connected in
series with the manifold of the cooktop and
must remain in series with the supply line
regardless of whether natural or L.P. gas is
being used. FOR PROPER OPERATION,
THE MAXIMUM INLET PRESSURE TO THE
REGULATOR MUST BE NO MORE THAN
14
OF WATER COLUMN PRESSURE. For
checking the regulator, the inlet pressure
must be at least 1
(or 3.4 KPA) greater than
the regulator output setting. If the regulator is
set for 4
of water column pressure, the inlet
pressure must be at least 5
. If the regulator
is set for 10
, the inlet pressure must be at
least 11
. The gas supply line to the cooktop
should be 1/2
or 3/4
pipe.
1
INSTALL REGULATOR
NEVER REUSE OLD CONNECTORS WHEN
INSTALLING THIS COOKTOP.
WARNING:
Never reuse old
flexible connectors. The use of old flexible
connectors can cause gas leaks and personal
injury. Always use new flexible connectors
when installing a gas appliance.
To reduce the likelihood of gas leaks, apply
teflon tape or a thread compound approved
for use with LP or Natural gases to all
threaded connections.
2
Screw a section of pipe
onto each end of the
pressure regulator.
INSTALL REGULATOR ONTO
BURNER BOX BOTTOM
Screw the
regulator and
pipe connection
into the burner
box bottom.
Make sure the
top of the
regulator is
facing towards
the cabinet front,
easily accessible
through the
cabinet doors.
3
COMPLETE CONNECTION
WITH A COUPLING
Install a coupling
between the
regulator and
the shu-off valve
to complete the
connection.
4
Pressure
Regulator
Pressure
Regulator
Shut-Off
Valve
Electrical
Outlet 12
Below
Countertop
Pressure
Regulator
Shut-Off
Valve
Coupling
Electrical
Outlet 12
Below
Countertop