Adapting Blower for Recirculation, AFTER: Fan Blade, Openings Facing, Forward
![]() |
View all GE SCA1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Installation Instructions C3. ADAPTING BLOWER FOR RECIRCULATION NOTE: The exhaust adaptor with damper is not needed for recirculating models. You may want to save them for possible future use. 1 Remove and save screws that hold blower plate to the oven. Blower Plate Screws 3 Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit. Back of Oven 2 Slide the blower plate from under its retaining flange and lift it off. Remove and save screw that holds the blower motor to oven. Retaining Flange Blower Plate Blower Motor Screw 4 Roll the blower unit 90° so that fan blade openings are facing toward the front of the oven. BEFORE: Fan Blade Openings Facing Up Roll AFTER: Fan Blade Openings Facing Forward NOTE: Make sure wires remain routed in the grooves of the motor frame. 20