Troubleshooting
View all GE asd06lk manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Troubleshootingtips... Air conditioner doesnotstart Possible Causes The air conditioner is unplugged, The fuse is bloval/circuit breaker is tripped, Power failure. Air conditioner does not cool as it should Air conditioner freezing up The remote controlis not working Water drips outside Waterdripsindoors Water collectsin basepan "El'appears in the display Timeror Sleepfeature notworkingproperly The current interrupter device is lripped. Airflow is resMcted. The temp conlrol may not be set correctly. The air Fdter is dirty. The room may have been hot. Cold air is escaping. Cooling coils have iced up. Ice blocks the air flow and stops the air conditioner from cooling the room. The batteries are htserted incorrectly, The batteries may be dead. Hot, humid weather. The air conditioner is not tilted to the outside, Moisture removed from air and drahls into base pan. Ftmcfion error code. A power outage or htterrupdon occurred. What To Do • Make sure tile ah" conditioner ph N is pushed completely into tile outlet. * Check file house fltse/circuit bx_aker box and replace the flLse or reset the breakec * If t)o_er f_filure occm_, turn tile ;fir contfitioner Off When po_er is restored, \_;fit 3 minutes to restart the air conditioner to prevent triplling of tile compressor o_erload. * Press tile Reset button located on file po_er cord plug. • If the Reset button will not stay eng_|ged, discontinue use of tile ;fir conditioner and contact a qu;flified seLvice technician. * Make sure there are no curtains, blinds or fnmimxe blocking the fi'ont of tile ;fir con(fitioner. * On models with touc]L pads: Ill Cool mode, press the Decrease• pad. • On models wiflLcontrol knobs, turn file temperature knob to a higher nurrLbex: • Clean tile tilter at least eveiw 30 dm\s. See the Operating Instructiotis secti(;n. • When file air conditioner is first turned on, you need to allo\x time for tile room to cool dox_al. • Check for open thrnace registers and cold air returns. • Set the air conditioner's vent to the closed position. • See "Air conditionerfreezingup"bellm. • On models wiflLcontrol knobs, set tile mode control at High Fan or High Cool\\ith the temp at I or 2. • OIl Ulodels \_ith touch pads, set tile controls at High Fanor High Cool and set tile thermostat to a higher mmperature. • Check file position of tile batteries. They should be inserted ill tile opposite (+) and (-) direction. • Replace the batteries. • This is normal. • For proper _Lter disposal, Lnake stu'e tile air conditioner slants slightl} fi'om the case fl'ont to the reax: • This is normal fbr a short period ill areas with little humidity; normal for a longer period ill \er\ humid areas. • U/lphlg tile air c(/nditiol/er Wait 3 l//il//l[es al/d plug it back ill. • Ill tile case of a power outage or interruption, the unit Timerand Sleepfeatures \_il] reset to tile original setting. _bu may need to set a ue\_ time if desired. Normal Operating Sounds You may hear a pinging noise caused by X._ater will collect in tile base pan during water being picked uI) and thrown against the high humidit}' or on rainy days. Tile water condenser on rainy days or when tile humidiP,' is high. This design feature helps relnove may overflow and drip from tile outdoor side of the unit. moisture and improve eflicienc'y. ; Tile lilll II/_:lV rlln even when tile COll/l)i'essor 78 You may hear tile them/ostat click when tile does not. compressor c'ycles on and off.