DRAM E.O.C.P, Set Memory Clock

Page 23 highlights

DRAM E.O.C.P Allows you to determine whether to use the preset memory overclocking profile to achieve optimum overclocking performance. (Default: Disabled) Set Memory Clock Determines whether to manually set the memory clock. Auto lets BIOS automatically set the memory clock as required. Manual allows the memory clock control item below to be configurable. (Default: Auto) Memory Clock This option is configurable only when Set Memory Clock is set to Manual. Options are: X4.00, X5.33, X6.66 and X8.00. DRAM Configuration CMOS Setup Utility-Copyright (C) 1984-2012 Award Software DRAM Configuration DCTs Mode DDR3 Timing Items x 1T/2T Command Timing x CAS# latency x RAS to CAS R/W Delay x Row Precharge Time x Minimum RAS Active Time x TwTr Command Delay x Trfc0 for DIMM1 x Trfc1 for DIMM2 x Write Recovery Time x Precharge Time x Row Cycle Time x RAS to RAS Delay [Unganged] [Auto] Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto SPD -9T 9T 9T 24T 5T 110ns -10T 5T 33T 4T Auto -6T 6T 6T 15T 4T 110ns -10T 5T 33T 4T Item Help Menu Level  Channel Interleaving Bank Interleaving DQS Training Control Memclock tri-stating Move Enter: Select F5: Previous Values [Enabled] [Enabled] [Skip DQS] [Disabled] +/-/PU/PD: Value F10: Save F6: Fail-Safe Defaults ESC: Exit F1: General Help F7: Optimized Defaults DCTs Mode Allows you to set memory control mode. Ganged Sets memory control mode to single dual-channel. Unganged Sets memory control mode to two single-channel. (Default) DDR3 Timing Items Manual allows all DDR3 Timing items below to be configurable. Options are: Auto (default), Manual. 1T/2T Command Timing Options are: Auto (default), 1T, 2T. CAS# latency Options are: Auto (default), 4T~12T. RAS to CAS R/W Delay Options are: Auto (default), 5T~12T. Row Precharge Time Options are: Auto (default), 5T~12T. Minimum RAS Active Time Options are: Auto (default), 15T~30T. - 23 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

- 23 -
DRAM E.O.C.P
Allows you to determine whether to use the preset memory overclocking profile to achieve optimum
overclocking performance. (Default: Disabled)
Set Memory Clock
Determines whether to manually set the memory clock.
Auto
lets BIOS automatically set the memory
clock as required.
Manual
allows the memory clock control item below to be configurable. (Default: Auto)
Memory Clock
This option is configurable only when
Set Memory Clock
is set to
Manual
. Options are: X4.00, X5.33,
X6.66 and X8.00.
DRAM Configuration
CMOS Setup Utility-Copyright (C) 1984-2012 Award Software
DRAM Configuration
DCTs Mode
[Unganged]
DDR3 Timing Items
[Auto]
SPD
Auto
x
1T/2T Command Timing
Auto
--
--
x
CAS# latency
Auto
9T
6T
x
RAS to CAS R/W Delay
Auto
9T
6T
x
Row Precharge Time
Auto
9T
6T
x
Minimum RAS Active Time
Auto
24T
15T
x
TwTr Command Delay
Auto
5T
4T
x
Trfc0 for DIMM1
Auto
110ns
110ns
x
Trfc1 for DIMM2
Auto
--
--
x
Write Recovery Time
Auto
10T
10T
x
Precharge Time
Auto
5T
5T
x
Row Cycle Time
Auto
33T
33T
x
RAS to RAS Delay
Auto
4T
4T
Channel Interleaving
[Enabled]
Bank Interleaving
[Enabled]
DQS Training Control
[Skip DQS]
Memclock tri-stating
[Disabled]

: Move
Enter: Select
+/-/PU/PD: Value
F10: Save
ESC: Exit
F1: General Help
F5: Previous Values
F6: Fail-Safe Defaults
F7: Optimized Defaults
Item Help
Menu Level
DCTs Mode
Allows you to set memory control mode.
Ganged
Sets memory control mode to single dual-channel.
Unganged
Sets memory control mode to two single-channel. (Default)
DDR3 Timing Items
Manual
allows all DDR3 Timing items below to be configurable.
Options are: Auto (default), Manual.
1T/2T Command Timing
Options are: Auto (default), 1T, 2T.
CAS# latency
Options are: Auto (default), 4T~12T.
RAS to CAS R/W Delay
Options are: Auto (default), 5T~12T.
Row Precharge Time
Options are: Auto (default), 5T~12T.
Minimum RAS Active Time
Options are: Auto (default), 15T~30T.