7 Q/A Phenomenon Water too hot Water temperature fluctuation Water too cold Without electricity When used, the power supply air switch tripping takes place It doesn't work in case of water supply Displays E3 Things to be confirmed 1. Water flow too low to water heater or external tap water temperature rising 2. Power too high Outlet water temperature higher than 58℃; the water heater is in the fixed temperature control working state 1. Water flow too high or power too low 2. Water pressure too low so that the water heater doesn't start up 3. Voltage fluctuation 4. Lower than the requirements of the product 1. Water pressure too low so that the water heater doesn't start up 2. Power off 3. Parts and components don't work or are damaged 1. Insufficient air switch capacity 2. Circuit fault of the water heater 1. Air switch tripping 2. The circuit is not connected 3. Over-temperature protection Sensor fault Solutions 1. Turn up the inlet water 2. Turn down the power As above 1. Reduce the inlet water or increase the power 2. Check whether the water source is sufficient; if water pressure needs to be increased, temporarily close other water valves in the house or install an additional pressure pump to increase water pressure 3. Return to normal voltage 4. Contact the repair & maintenance department 1. If the water pressure needs to be increased, temporarily close other water valves in the house or install an additional pressure pump to increase water pressure 2. Have the circuit checked by professional personnel 3. Contact with the repair & maintenance department 1. Replace air switch 2. Have it checked by qualified professional personnel Have the circuit checked and repaired by professional personnel Have the circuit checked and repaired by professional personnel

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13

7
Q/A
Phenomenon
Things to be confirmed
Solutions
Water too hot
1.
Water flow too low to water heater
or external tap water temperature
rising
2.
Power too high
1.
Turn up the inlet water
2.
Turn down the power
Water temperature fluctuation
Outlet water temperature higher than
58
; the water heater is in the fixed
temperature control working state
As above
Water too cold
1.
Water flow too high or power too
low
2.
Water pressure too low so that the
water heater doesn’t start up
3.
Voltage fluctuation
4.
Lower than the requirements of the
product
1.
Reduce the inlet water or
increase the power
2.
Check whether the water
source is sufficient; if water
pressure needs to be
increased, temporarily close
other water valves in the
house or install an additional
pressure pump to increase
water pressure
3.
Return to normal voltage
4.
Contact the repair &
maintenance department
Without electricity
1.
Water pressure too low so that the
water heater doesn’t start up
2.
Power off
3.
Parts and components don’t work or
are damaged
1.
If the water pressure needs to
be increased,
temporarily
close other water valves in
the house or install an
additional pressure pump to
increase water pressure
2.
Have the circuit checked by
professional personnel
3.
Contact with the repair &
maintenance department
When used, the power supply
air switch tripping takes place
1.
Insufficient air switch capacity
2.
Circuit fault of the water heater
1.
Replace air switch
2.
Have it checked by qualified
professional personnel
It doesn’t work in case of
water supply
1.
Air switch tripping
2.
The circuit is not connected
3.
Over-temperature protection
Have the circuit checked and
repaired by professional
personnel
Displays E3
Sensor fault
Have the circuit checked and
repaired by professional
personnel