Electric wiring

Page 30 highlights

Installation procedures Electric wiring Wiring method 1.The wiring method of orbicular terminal For the connection wire which end is orbicular terminal, its wiring method is as the right figure shown. Dismantle the screw and put it through the ring at the end of the connection wire, then connect it to the terminal block and tighten the screw. The wiring method of orbicular terminal 2.The wiring method of straight terminal For those connection wires whose end are not orbicular terminals, their wiring method is: Loosen the connecting screw, insert the end of the wire directly into the terminal block, and then tighten screw. Pull the wire outwards slightly to confirm it is held tightly. 3.Pressing method of connection wire: After wiring, the connection wire must be pressed with wire holding clamp. The wire Correct pressing Wrong pressing Terminal block holding clamp should press on the out cover of the connection wire. As the right fi- Wire holding clamp gure shown: (Sketch map) 4. Lengthen power cord It must use a whole piece of power cord when it is lengthened.Do not lengthen by connection. When lengthen feeble current signal wire, the connecting wire must be 100mm staggered and welded firmly. Wire connecting of outdoor unit Remove the electric box cover. Connect the connecting wire properly according to wiring method and wiring diagram of indoor & outdoor unit. Press the connecting wire properly according to the connecting wire pressing method. Reinstall the electric box cover. Terminal Wire holding clamp Pre-remained wire Wire connecting of indoor unit Terminal block (indoor) Remove the air inlet grille and open the control box cover. Introduce the front end of connecting wire out. Connect the connectign wire properly according to wiring method and wiring diagram of indoor & Terminal block (outdoor) outdoor unit. HPU-23CB03 Press the connecting wire properly according to connecting wire pressing method. Reinstall the control box cover and air inlet grille properly. Power cord (User self-provided) Power : 1PH,220-230V~,50Hz Special switch over 30A (The parts in dotted line are user self-provided) Note: The electric wire must be copper-core wire. Tyep of connecting wire: YZW. Terminal block (indoor) Power : 1PH,220-230V~,50Hz KF-48LW/K(XF): 3x2.0mm2 2x0.75 mm2 Power supply: 1PH,220V~,50Hz, and is connected from indoor unit. KF-68LW/K(XF): 4x0.75 mm2 Power supply: 1PH,220V~,50Hz, and is connected from outdoor unit. 28 Indoor unit casing Terminal block (outdoor) HPU-16CB03

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

(Sketch map)
Installation procedures
Power cord
(User self-provided)
Special switch over 30A
(The parts in dotted line are user self-provided)
2
2
2
Electric wiring
2.The wiring method of straight terminal
For those connection wires whose end are not orbicular terminals, their
wiring method is:
Loosen the connecting screw, insert the end of the wire directly into the terminal
block, and then tighten screw. Pull the wire outwards slightly to confirm it is held
tightly.
3
.
Pressing method of connection wire:
After wiring, the connection wire must be
pressed with wire holding clamp. The wire
holding clamp should press on the out co-
ver of the connection wire. As the right fi-
gure shown:
Wiring method
1.The wiring method of orbicular terminal
For the connection wire which end is orbicular
terminal, its wiring method is as the right figure
shown. Dismantle the screw and put it through
the ring at the end of the connection wire, then
connect it to the terminal block and tighten the
screw.
The wiring method of orbicular terminal
Correct pressing
Terminal block
Wire holding clamp
Wrong pressing
4. Lengthen power cord
It must use a whole piece of power cord when it is lengthened.Do not lengthen by
connection. When lengthen feeble current signal wire, the connecting wire must be
100mm staggered and welded firmly.
Wire connecting of outdoor unit
Remove the electric box cover.
Connect the connecting wire properly according to wiring
method and wiring diagram of indoor & outdoor unit.
Press the connecting wire properly according to the
connecting wire pressing method.
Reinstall the electric box cover.
Terminal
Wire holding
clamp
Pre-remained wire
Wire connecting of indoor unit
Remove the air inlet grille and open the
control box cover.
Introduce the front end of connecting wire out.
Connect the connectign wire properly according
to wiring method and wiring diagram of indoor &
outdoor unit.
Press the connecting wire properly according to
connecting wire pressing method.
Reinstall the control box cover and air inlet grille
properly.
Power supply: 1PH,220V~,50Hz, and is connected from
outdoor unit.
HPU-16CB03
Indoor unit casing
Terminal block (outdoor)
Terminal block (indoor)
Power : 1PH,220-230V~,50Hz
HPU-23CB03
Terminal block (outdoor)
Terminal block (indoor)
Power : 1PH,220-230V~,50Hz
Note:
The electric wire must be copper-core wire.
Tyep of connecting wire: YZW.
Power supply: 1PH,220V~,50Hz, and is connected from
indoor unit.
KF-48LW/K(XF):
3x2.0mm
2x0.75 mm
KF-68LW/K(XF):
4x0.75 mm
28