Installation of indoor unit

Page 27 highlights

Installation procedures Installation of indoor unit Selection of installation place Place where it is easy to route drainage pipe and outdoor piping. Place away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evenly to every corner of the room. Place near power supply socket. Leave enough space around the unit (refer to installation drawings). Fixing of the unit 1. Position of the wall hole Wall hole should be decided according to installtion place and piping direction. (refer to installation drawings) 2. Making a wall hole Drill a hole of 70mm dia. with a little slope towards outside. Install piping hole cover and seal it with putty after installation. INDOOR OUTDOOR UNIT wall hole 70mm wall thinkness Fixing of indoor unit ( Cross section of wall hole ) To prevent it from fall off, please fix the unit with fall-prevention fitting at wall and L-shaped metal at floor. Self-tapping screw all-prevention fitting metal (accessory) Wood screw Please install the whole unit horizontally,with a slop of 1 degree at L-shaped metal front and rear,left and right. (accessory) 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

Installation procedures
25
Installation of indoor unit
Selection of installation place
Place where it is easy to route drainage pipe and outdoor piping.
Place away from heat source and with less direct sunlight.
Place where cool and warm air could be delivered evenly to every corner of the room.
Place near power supply socket. Leave enough space
around the unit (refer to installation
drawings).
Fixing of the unit
Position of the wall hole
Wall hole should be decided according to installtion place and piping direction. (refer
to installation drawings)
Making a wall hole
Drill a hole of 70mm dia. with a little slope towards outside.
Install piping hole cover and seal it with putty after installation.
1.
2.
Fixing of indoor unit
To prevent it from fall off, please fix the unit with fall-prevention fitting at wall and
L-shaped metal at floor.
INDOOR
OUTDOOR UNIT
wall hole
wall thinkness
( Cross section of wall hole )
70mm
Self-tapping
screw
all-prevention fitting metal (accessory)
Wood screw
L-shaped metal
(accessory)
Please install the whole unit
horizontally,with a slop of 1 degree at
front and rear,left and right.