Haier PRCS25TDAS User Guide - Page 9
Connect the tubing to the valve, Flush out the tubing, Connect the tubing to the refrigerator
View all Haier PRCS25TDAS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
Connecting the Water Supply Line Connect the tubing to the valve: Place the compression nut and ferrule (sleeve) for copper onto the end of the tubing and connect it to the shutoff valve. Make sure the tubing is fully inserted into the valve. Tighten the compression nut securely. Commonwealth of Massachusetts Plumbing Codes 248CMR must be adhered to. Saddle vales are illegal and use is not permitted in Massachusetts. Consult with your licensed plumber. Flush out the tubing: Turn the main water supply on and flush out the tubing until the water is clear. Shut the water off at the water valve after about one quart (1 liter) of water has been flushed through the tubing. Connect the tubing to the refrigerator: Before making the connection to the refrigerator, be sure the refrigerator power cord is not plugged into the wall outlet. a.Remove the plastic flexible cap from the water valve. b.Place the compression nut and ferrule (sleeve) onto the end of the tubing as shown. After install the water line,please confirm that there is no leakage in every connection piont before using the refrigerator.