The Aqua Rite Pro periodically reverses the polarity of the voltage applied to the cell in order to automatically clean off any calcium deposits that may have built up on the cell. It is important that you check the chlorinator operation in both polarities. To do this, press either the "+" or "-" buttons and the chlorinator will turn off, wait for 15 seconds and then turn on in the opposite polarity. Salt Level 3200 PPM No function Move to previous/next menu item This is the average "Salt Level" in the pool. This value is calculated over time and minimizes the effects of spikes or dips that may naturally occur. Instant Salt 3200 PPM (+=save) Press to load the "Instant Salt" into the averaged salt display Move to previous/next menu item The "Instant Salt" is calculated based on the voltage, current (amps), and water temperature at the cell at that instant. There are a number of reasons why instant and average salt readings may differ. Some of these include salt having just been added to the pool and not yet thoroughly mixed, calcium buildup on the cell, and cell aging. Press the "+" button to enter the instant salt value into the average salt level. The average salt level will use this new value for its calculations. Flow Switch Flow No function Move to previous/next menu item The current status of the flow switch is displayed. There is a short delay when transitioning from flow to no-flow and a longer delay on the transition from no-flow to flow. The delay time is displayed. Main Software Revision 2.40 No function Move to previous/next menu item Display Software Revision 3.10 No function Move to previous/next menu item Chemistry Sense Software r1.00 No function Move to previous/next menu item Available displays depend on configuration. These displays show the software revisions of various components. Inspect Cell hold + to reset Press to reset Move to previous/next menu item For optimum operation, you will need to inspect the Aqua Rite Pro chlorinator cell approximately every 3 months and clean the cell if necessary. The Aqua Rite Pro will automatically remind you and display "Inspect Cell, hold + to reset" as part of the rotating Information Menu. Clean the cell and then press the "+" button during the "Inspect Cell" display to reset the timer. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

8
The Aqua Rite Pro periodically reverses the polarity of the voltage
applied to the cell in order to automatically clean off any calcium
deposits that may have built up on the cell.
It is important that you
check the chlorinator operation in both polarities.
To do this, press
either the “+” or “-“ buttons and the chlorinator will turn off, wait for
15 seconds and then turn on in the opposite polarity.
Salt Level
3200 PPM
No function
Move to previous/next menu item
This is the average "Salt Level" in the pool. This value is calculated
over time and minimizes the effects of spikes or dips that may naturally
occur.
Instant Salt
3200 PPM (+=save)
Move to previous/next menu item
Press to load the “Instant Salt” into the averaged salt display
The “Instant Salt” is calculated based on the voltage, current (amps),
and water temperature at the cell at that instant.
There are a number of
reasons why instant and average salt readings may differ.
Some of
these include salt having just been added to the pool and not yet
thoroughly mixed, calcium buildup on the cell, and cell aging.
Press the "+" button to enter the instant salt value into the average
salt level.
The average salt level will use this new value for its
calculations.
Flow Switch
Flow
No function
Move to previous/next menu item
The current status of the flow switch is displayed.
There is a short
delay when transitioning from flow to no-flow and a longer delay on
the transition from no-flow to flow.
The delay time is displayed.
Main Software
Revision 2.40
Display Software
Revision 3.10
No function
No function
Move to previous/next menu item
Move to previous/next menu item
Chemistry Sense
Software r1.00
No function
Move to previous/next menu item
Available displays depend on configuration.
These displays show
the software revisions of various components.
Inspect Cell
hold + to reset
Press to reset
Move to previous/next menu item
For optimum operation, you will need to inspect the Aqua Rite Pro
chlorinator cell approximately every 3 months and clean the cell if
necessary. The Aqua Rite Pro will automatically remind you and display
“Inspect Cell, hold + to reset” as part of the rotating Information
Menu. Clean the cell and then press the “+” button during the “Inspect
Cell” display to reset the timer.