Page 5 highlights

Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Fittings Fittings restrict flow. For better efficiency, use the fewest possible fittings. Avoid fittings that could cause an air trap. Pool and spa fittings MUST conform to the International Association of Plumbing and Mechanical Officials (IAPMO) standards. Use a non-entrapping suction fitting in pool or double suction (skimmer and main drain). Electrical WARNING - Ground motor before connecting to electrical power supply. Failure to ground pump motor can cause serious or fatal electrical shock hazard. WARNING - Do NOT ground to a gas supply line. WARNING - To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. WARNING - Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical problem. If GFCI trips and won't reset, consult electrician to inspect and repair electrical system. WARNING - Fire Hazard. Match supply voltage to motor nameplate voltage. Insure that the electrical supply available agrees with the motor's voltage, phase, and cycle, and that the wire size is adequate for the H.P. (KW) rating and distance from the power source. NOTE: All electrical wiring MUST be performed by a qualified professional, and MUST conform to local codes and regulations. Voltage Voltage at motor MUST NOT be more than 10% above or below motor name plate rated voltage, or motor may overheat, causing overload tripping and reduced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company. Grounding/Bonding Install, ground, bond, and wire motor according to local or national electrical code requirements. Permanently ground motor. Use green ground terminal provided under motor canopy or access place; use size and type wire required by code. Connect motor ground terminal to electrical service ground. Bond motor to pool structure. Use a solid copper conductor, size or larger. Run wire from external bonding lug to reinforcing rod or mesh. Connect a No. 8 AWG (8.4 mm2) solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping or conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub. Wiring Pump MUST be permanently connected to circuit. If other lights or appliances are also on the same circuit, be sure to add their amp loads before figuring wire and circuit breaker sizes. (NOTE: If unsure how to do this or if this is confusing, consult a licensed electrician). Use the load circuit breaker as the Master On-Off switch. Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short-circuit to ground and disconnect power before it becomes dangerous to pool users. For size of GFCI required and test procedures for GFCI, see manufacturer's instructions.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Power-Flo
LX™ / Power-Flo II™ Pump Series_____________________________________________
Installation Instructions (cont.)
Fittings
Fittings restrict flow.
For better efficiency, use the fewest possible fittings.
Avoid fittings that could cause an air trap.
Pool and spa fittings MUST conform to the International Association of Plumbing and Mechanical Officials (IAPMO)
standards.
Use a non-entrapping suction fitting in pool or double suction (skimmer and main drain).
Electrical
WARNING –
Ground motor before connecting to electrical power supply.
Failure to ground pump motor can cause serious or fatal electrical shock hazard.
WARNING –
Do NOT ground to a gas supply line.
WARNING –
To avoid dangerous or fatal electrical shock, turn OFF power to
motor before working on electrical connections.
WARNING –
Ground Fault Circuit Interrupter (GFCI) tripping indicates
electrical problem.
If GFCI trips and won’t reset, consult electrician to inspect and repair electrical
system.
WARNING
Fire Hazard.
Match supply voltage to motor nameplate voltage.
Insure that the electrical supply available agrees with the motor’s voltage, phase, and cycle, and that the wire size is
adequate for the H.P. (KW) rating and distance from the power source.
NOTE: All electrical wiring MUST be performed by a qualified professional, and MUST conform to local
codes and regulations.
Voltage
Voltage at motor
MUST NOT
be more than 10% above or below motor name plate rated voltage, or motor
may overheat, causing overload tripping and reduced component life.
If voltage is less than 90% or more
than 110% of rated voltage when motor is running at full load, consult power company.
Grounding/Bonding
Install, ground, bond, and wire motor according to local or national electrical code requirements.
Permanently ground motor.
Use green ground terminal provided under motor canopy or access place; use
size and type wire required by code.
Connect motor ground terminal to electrical service ground.
Bond motor to pool structure.
Use a solid copper conductor, size or larger.
Run wire from external bonding
lug to reinforcing rod or mesh.
Connect a No. 8 AWG (8.4 mm
2
) solid copper bonding wire to the pressure
wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hot
tub, and to all electrical equipment, metal piping or conduit within 5 ft. (1.5 m) of inside walls of swimming
pool, spa, or hot tub.
Wiring
Pump MUST be permanently connected to circuit.
If other lights or appliances are also on the same circuit,
be sure to add their amp loads before figuring wire and circuit breaker sizes.
(NOTE:
If unsure how to do
this or if this is confusing, consult a licensed electrician).
Use the load circuit breaker as the Master On-Off
switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short-circuit to ground and
disconnect power before it becomes dangerous to pool users.
For size of GFCI required and test procedures
for GFCI, see manufacturer’s instructions.