Hayward Pro Logic Model: PL-P-4 Operation - Page 17

e3 Pump Speed - pool panel no flow

Page 17 highlights

Valve3 Config. + to view/change Push to access Valve3 options Move to previous/next configuration menu Valve3 Function Rotates Timeclock (default), Solar, In-floor Cleaner and Super Chlorinate Solar Move to next menu item for all functions except solar and super chlorinate Valve3 Interlock Toggle between Enabled and Disabled (default) Valve3 Interlock Disabled Move to next menu item for all functions except solar and super chlorinate Valve3 Ext Input Toggle between Enabled and Disabled (default) Disabled Move to previous/next configuration menu for all functions except super chlorinate Valve3 Freeze Toggle between Enabled and Disabled (default) Valve3 Freeze Disabled Move to previous/next configuration menu if filter pump is set to variable speed and the relay type is set to standard Valve3 Pump Spd Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest) Settings Menu Move to previous/next configuration menu Valve3 Function Timeclock (default) - the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see Operations Manual). The VALVE3 button can also be used to turn the valve output on or off. Solar - the valve operates when the filter pump is running and solar heat is available and the water is less than the desired temperature setting. Solar heating must be enabled in the "Solar Config. menu for proper operation to occur. In-Floor Cleaner - the valve switches the water returning to the pool between the in-floor cleaner and the normal return jets which facilitate efficient surface skimming. The valve will operate the in-floor cleaner for the first half of each clock hour and then switch to the jets/skimming for the last half of the hour. Super Chlorinate - if "Chlorinator" is enabled, this option allows the user to start a Super Chlorinate cycle when the Valve3 button is pressed, rather than using the Settings Menu. Note that only one button can be assigned to this function. Valve3 Interlock If "Enabled", this feature will override the function (timeclock or in-floor cleaner) selected above and turn the valve off when: the filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime and get water flowing), or for the first 3 minutes after solar turns on (allows air in the solar panels to be purged). Interlock is not available for solar or super chlorinate. Valve3 External Input Interlock When Valve3 External Input Interlock is enabled, the Valve3 output will be forced off when the external input is active. This will have precedence over freeze protection. Valve3 External Input Interlock is not available for solar and super chlorinate. Valve3 Freeze Protection This function protects the pool and plumbed equipment against freeze damage. If Freeze Protection is enabled and the AIR temperature falls sensor falls below the selected freeze temperature threshold, the Pro Logic will turn on the valve to allow circulation of the water. IMPORTANT: this only enables operation of the valve3 output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation system. Valve3 Pump Speed This is the speed of the pump when the Valve3 output is on. The default selection is "Settings Menu". This is the speed of the pump that has been selected in the Settings Menu for normal filter operation. If an alternate speed is desired when the Valve3 output is on, push "+" or "-" and select from "Filter Lowest" to "Filter Highest" in 5% increments. 21 Pool/Spa Config. + to view/change Push to access Pool/Spa options Move to previous/next configuration menu Pool/Spa Setup Pool and Spa if "Pool and Spa" is selected Spa - CountDn 00:30 Rotates between Pool Only (default), Spa Only and Pool and Spa Move to next menu item Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00)) Move to next menu item if "Pool and Spa" is selected Spa Spillover Toggle between Enabled and Disabled (default) Spa Spillover Enabled Move to next menu item or previous/next configuration menu if "Pool and Spa" is selected and if "Spa Spillover" is enabled Filter Operation Spa Spillover Toggle between Pool Only (default) and Spa Spillover options Move to previous/next configuration menu if "Pool Only" or "Spa Only" is selected V1=Aux1, V2=Aux2 Toggle between Enabled and Disabled (default) Disabled Move to previous/next configuration menu if "Pool and Spa" is selected Filter Off Valve Change: Enabled Toggle between Enabled (default) and Disabled Move to previous/next configuration menu Pool/Spa Setup If "Pool Only" or "Spa Only" are selected, then the pool/spa valves are not needed and pushing the POOL/SPA button on the display/keypad will have no effect. If "Pool and Spa" is selected, then the pool/spa suction and return valve actuators should be connected to the Pro Logic. Pressing the POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and spa operation. Spa CountDn This menu will appear only if Pool/Spa Setup is set to "Pool and Spa". This setting is the time, after you manually switch the Pool/Spa valves to "Spa Only", until the Pro Logic automatically returns the valves to their previous positions. It is programmed in increments of 5 minutes, from "Manual On/Off" (0 minutes) to "21:00" (21 hours). The filter is forced on during this time period. Spa Spillover When spa spillover is "Enabled" and "Pool and Spa", the homeowner will be able to rotate through "Pool Only" (both suction and return valves switched to pool), "Spa Only" (both suction and return valves switched to spa) and "Spillover" (suction valve switched to pool and return valve switched to spa) by successive presses of the "Pool/Spa button. Filter Operation If "Spa Spillover" is selected, the Pro Logic will automatically switch the pool/spa suction and return valves to "spillover" at the start of the programmed pool filtering time period or when the superchlorinate function is turned on. The valves will remain in this position for the remainder of the superchlorinate period. This option is usually preferable because both the pool and spa water will be filtered and sanitized. If "Pool Only" is selected, then the Pro Logic will switch the pool/spa valves to the "pool only" position at the start of the programmed pool filtering time period or when the super-chlorinate function is turned on. This may be desirable on some systems with in-floor cleaners because it allows the cleaner to operate all the time the pool is being filtered and/or the super chlorinate is running. V1=Aux1, V2=Aux2 This menu appears only if the Pool/Spa Setup is "Pool Only" or "Spa Only". When enabled, Valve 1 (return) will follow the Aux1 output and Valve 2 (suction) will follow the Aux2 output. When disabled (default), the return and suction pool/spa valves function normally. Filter Off Valve Change This menu appears only if Pool/Spa setup is set to "Pool and Spa - Std". When enabled (default), the filter pump will shut off for 35 seconds whenever the Pool/Spa valves are turning. The pump will NOT shut off when a heater is in Heater Cooldown mode. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

14
Pool/Spa Config.
+ to view/change
Pool/Spa Setup
Pool and Spa
Spa Spillover
Enabled
Filter Operation
Spa Spillover
Push to access Pool/Spa options
Rotates between Pool Only (default), Spa Only and
Pool and Spa
Toggle between Enabled and Disabled
Spa Spillover
(default)
Toggle between Pool Only
and Spa Spillover
options
(default)
Move to previous/next configuration menu
Move to next menu item
Move to next menu item or previous/next configuration menu
Move to previous/next configuration menu
if “Pool and Spa” is
selected and
if “Spa Spillover” is enabled
Spa - CountDn
00:30
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
Move to next menu item
if “Pool and Spa” is selected
if “Pool and Spa” is selected
V1=Aux1, V2=Aux2
Disabled
Toggle between Enabled and Disabled (default)
if “Pool Only” or “Spa Only” is selected
Move to previous/next configuration menu
Filter Off Valve
Change: Enabled
Toggle between Enabled
and Disabled
(default)
if “Pool and Spa” is selected
Move to previous/next configuration menu
Pool/Spa Setup
If “Pool Only” or “Spa Only” are selected, then the pool/spa valves are not needed and pushing the
POOL/SPA button on the display/keypad will have no effect.
If “Pool and Spa” is selected, then the
pool/spa suction and return valve actuators should be connected to the Pro Logic.
Pressing the
POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and spa
operation.
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to “Pool and Spa”.
This setting is the time, after
you manually switch the Pool/Spa valves to “Spa Only”, until the Pro Logic automatically returns the
valves to their previous positions. It is programmed in increments of 5 minutes, from “Manual On/Off”
(0 minutes) to “21:00” (21 hours).
The filter is forced on during this time period.
Spa Spillover
When spa spillover is “Enabled” and “Pool and Spa”, the homeowner will be able to rotate through
“Pool Only” (both suction and return valves switched to pool), “Spa Only” (both suction and return
valves switched to spa) and “Spillover” (suction valve switched to pool and return valve switched to
spa) by successive presses of the “Pool/Spa button.
Filter Operation
If “Spa Spillover” is selected, the Pro Logic will automatically switch the pool/spa suction and return
valves to “spillover” at the start of the programmed pool filtering time period or when the super-
chlorinate function is turned on.
The valves will remain in this position for the remainder of the super-
chlorinate period.
This option is usually preferable because both the pool and spa water will be
filtered and sanitized.
If “Pool Only” is selected, then the Pro Logic will switch the pool/spa valves to the “pool only”
position at the start of the programmed pool filtering time period or when the super-chlorinate func-
tion is turned on.
This may be desirable on some systems with in-floor cleaners because it allows the
cleaner to operate all the time the pool is being filtered and/or the super chlorinate is running.
V1=Aux1, V2=Aux2
This menu appears only if the Pool/Spa Setup is “Pool Only” or “Spa Only”.
When enabled, Valve 1
(return) will follow the Aux1 output and Valve 2 (suction) will follow the Aux2 output.
When disabled
(default), the return and suction pool/spa valves function normally.
Filter Off Valve Change
This menu appears only if Pool/Spa setup is set to “Pool and Spa - Std”.
When enabled (default), the
filter pump will shut off for 35 seconds whenever the Pool/Spa valves are turning.
The pump will NOT
shut off when a heater is in Heater Cooldown mode.
21
Valve3
Disabled
Freeze
Toggle between Enabled and Disabled (default) Valve3 Freeze
Move to previous/next configuration menu
for all functions except super chlorinate
Valve3 Config.
+ to view/change
Valve3 Function
Solar
Push to access Valve3 options
Rotates
Timeclock (default), Solar, In-floor Cleaner and Super Chlorinate
Move to previous/next configuration menu
Move to next menu item
Valve3
Disabled
Interlock
Toggle between Enabled and Disabled (default) Valve3 Interlock
Move to next menu item
for all functions except solar and super chlorinate
for all functions except solar and super chlorinate
Valve3 Ext Input
Disabled
Toggle between Enabled and Disabled (default)
Move to previous/next configuration menu
if filter pump is set to variable speed
and the relay type is set to standard
Valve3 Pump Spd
Settings Menu
Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest)
Move to previous/next configuration menu
Valve3 Function
Timeclock (default)
– the valve turns on/off at the times set for the valve3 timeclock in the Timers
Menu (see Operations Manual).
The VALVE3 button can also be used to turn the valve output on or
off.
Solar
– the valve operates when the filter pump is running
and solar heat is available
and the water is
less than the desired temperature setting.
Solar heating must be enabled in the “Solar Config. menu
for proper operation to occur.
In-Floor Cleaner
– the valve switches the water returning to the pool between the in-floor cleaner and
the normal return jets which facilitate efficient surface skimming.
The valve will operate the in-floor
cleaner for the first half of each clock hour and then switch to the jets/skimming for the last half of the
hour.
Super Chlorinate
– if “Chlorinator” is enabled, this option allows the user to start a Super Chlorinate
cycle when the Valve3 button is pressed, rather than using the Settings Menu.
Note that only one
button can be assigned to this function.
Valve3 Interlock
If “Enabled”, this feature will override the function (timeclock or in-floor cleaner) selected above and
turn the valve off when:
the filter pump is off, first 3 minutes of filter pump operation (allows the pump
to prime and get water flowing), or for the first 3 minutes after solar turns on (allows air in the solar
panels to be purged).
Interlock is not available for solar or super chlorinate.
Valve3 External Input Interlock
When Valve3 External Input Interlock is enabled, the Valve3 output will be forced off when the external
input is active.
This will have precedence over freeze protection. Valve3 External Input Interlock is not
available for solar and super chlorinate.
Valve3 Freeze Protection
This function protects the pool and plumbed equipment against freeze damage.
If Freeze Protection
is enabled and the AIR temperature falls sensor falls below the selected freeze temperature threshold,
the Pro Logic will turn on the valve to allow circulation of the water.
IMPORTANT:
this only enables
operation of the valve3 output during freeze--see the “Filter Pump Config.” menu to enable freeze
protection for the main circulation system.
Valv
e3 Pump Speed
This is the speed of the pump when the Valve3 output is on.
The default selection is “Settings Menu”.
This is the speed of the pump that has been selected in the Settings Menu for normal filter operation.
If an alternate speed is desired when the Valve3 output is on, push “+” or “-” and select from “Filter
Lowest” to “Filter Highest” in 5% increments.