Hayward TriStar All TriStar models - Page 9

Maintenance, Storage/Winterization, WARNING, ATTENTION, ATTENTION, Shaft Seal Change Instructions, - pump manual

Page 9 highlights

TriStar™ Pump Series Page 9 of 15 Maintenance Clean strainer basket regularly. Do NOT strike basket to clean. Inspect strainer cover gasket regularly and replace as necessary. Hayward pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary. Keep motor clean. Insure motor air vents are free from obstruction to avoid damage. Do NOT use water to hose off motor. Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly kit. See "Shaft Seal Change Instructions" in this manual. Storage/Winterization WARNING - Separation Hazard. Do not purge the system with compressed air. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, filter, or piping. ATTENTION - Allowing the pump to freeze will void the warranty. ATTENTION - Use ONLY propylene glycol as antifreeze in your pool/spa system. Propylene glycol is non- toxic and will not damage plastic system components; other anti-freezes are highly toxic and may damage plastic components in the system. Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions below). Gravity drain system as far as possible. Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do NOT cover or wrap pump with plastic film or bags. Storing Pump For Winterization WARNING - To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining pump. Failure to disconnect power may result in serious personal injury or death. 1. Drain water level below all inlets to the pool. 2. Remove drain plugs and strainer cover from strainer housing. (See Parts Diagram on page 11 of this manual for pump component locations.) 3. Disconnect pump from mounting pad, wiring (after power has been turned OFF), and piping. 4. Once the pump is removed of water, re-install the strainer cover and drain plugs. Store pump in a dry area. Shaft Seal Change Instructions IMPORTANT SAFETY INSTRUCTIONS PLEASE READ AND FOLLOW ALL INSTRUCTIONS When servicing electrical equipment, basic safety precautions should always be observed including the following. Failure to follow instructions may result in injury. A. WARNING - To reduce risk of injury, do not permit children to use this product. B. Disconnect all electrical power service to pump before beginning shaft seal replacement. C. Only qualified personnel should attempt rotary seal replacement. Contact your local authorized Hayward Dealer or service center if you have any questions. Exercise extreme care in handling both the rotating and the stationary sections of the two-part replacement seal. Foreign matter or improper handling will easily scratch the graphite and ceramic sealing surfaces. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

TriStar
Pump Series ____________________
____________________________Page 9 of 15
Maintenance
±
Clean strainer basket regularly.
Do NOT strike basket to clean.
Inspect strainer cover gasket regularly and replace as
necessary.
±
Hayward pumps have self-lubricating motor bearings and shaft seals.
No lubrication is necessary.
±
Keep motor clean.
Insure motor air vents are free from obstruction to avoid damage.
Do NOT use water to hose off
motor.
±
Occasionally, shaft seals must be replaced, due to wear or damage.
Replace with genuine Hayward seal assembly kit.
See “Shaft Seal Change Instructions” in this manual.
Storage/Winterization
WARNING –
Separation Hazard.
Do not purge the system with compressed air.
Purging
the system with compressed air can cause components to explode, with risk of severe injury or death to
anyone nearby.
Use only a low pressure (below 5 PSI), high volume blower when air purging the pump,
filter, or piping.
ATTENTION
Allowing the pump to freeze will void the warranty.
ATTENTION –
Use ONLY propylene glycol as antifreeze in your pool/spa system.
Propylene glycol is non-
toxic and will not damage plastic system components; other anti-freezes are highly toxic and may damage plastic components
in the system.
Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see
instructions below).
Gravity drain system as far as possible.
Keep motor dry and covered during storage.
To avoid condensation/corrosion problems, do NOT cover or wrap pump with
plastic film or bags.
Storing Pump For Winterization
WARNING –
To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor
before draining pump.
Failure to disconnect power may result in serious personal injury or death.
1.
Drain water level below all inlets to the pool.
2.
Remove drain plugs and strainer cover from strainer housing.
(See Parts Diagram on page 11 of
this manual for pump component locations.)
3.
Disconnect pump from mounting pad, wiring (after power has been turned OFF), and piping.
4.
Once the pump is removed of water, re-install the strainer cover and drain plugs.
Store pump in a
dry area.
Shaft Seal Change Instructions
IMPORTANT SAFETY INSTRUCTIONS
PLEASE READ AND FOLLOW ALL INSTRUCTIONS
When servicing electrical equipment, basic safety precautions should always be observed including the following.
Failure to follow
instructions may result in injury.
A.
WARNING
To reduce risk of injury, do not permit children to use this product.
B.
Disconnect all electrical power service to pump before beginning shaft seal replacement.
C.
Only qualified personnel should attempt rotary seal replacement.
Contact your local authorized Hayward Dealer or
service center if you have any questions.
Exercise extreme care in handling both the rotating and the stationary sections of the two-part replacement seal.
Foreign matter or
improper handling will easily scratch the graphite and ceramic sealing surfaces.
WWW.HAYWARDPOOL.COM
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS