MAINTENANCE AND TROUBLESHOOTING MAINTENANCE Regular maintenance is important for optimal performance and to reduce wear. Inspect and properly tighten all parts each time the elliptical is used. Replace any worn parts immediately. Next, look into the access opening and locate the Reed Switch (58). Rotate the Pulley (66) until a Magnet (41) is aligned with the Reed Switch. Note: For clarity, the shields are shown removed in the drawing below. To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. 61 41 58 CONSOLE TROUBLESHOOTING 66 If the console does not display your heart rate when you hold the handgrip heart rate monitor, or if the displayed heart rate appears to be too high or too low, see step 5 on page 13. If a replacement power adapter is needed, call the telephone number on the cover of this manual. IMPORTANT: To avoid damaging the console, use only a manufacturer-supplied regulated power adapter. HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, first unplug the power adapter. Next, remove the four M4 x 16mm 37 Screws (not shown) from the Large Storage 27 Foot (27), and then remove the Large Storage Foot. Remove the two M4 x 16mm Screws (not shown) from the Top Shield (37), and then use a standard screwdriver to pry the Top Shield upward off the elliptical. Next, loosen, but do not remove, the two indicated M4 x 16mm Screws (61). Slide the Reed Switch (58) slightly toward or away from the Magnet (41). Then, retighten the M4 x 16mm Screws. Plug in the power adapter and rotate the pulley for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, unplug the power adapter and reattach the top shield and the large storage foot. Then, plug in the power adapter. 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

16
MAINTENANCE
Regular maintenance is important for optimal per-
formance and to reduce wear. Inspect and properly
tighten all parts each time the elliptical is used.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 13.
If a replacement power adapter is needed, call the
telephone number on the cover of this manual.
IMPORTANT: To avoid damaging the console, use
only a manufacturer-supplied regulated power
adapter.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, first
unplug the power adapter.
Next, remove the
four M4 x 16mm
Screws (not
shown) from the
Large Storage
Foot (27), and
then remove the
Large Storage
Foot. Remove the
two M4 x 16mm
Screws (not
shown) from the
Top Shield (37), and then use a standard screwdriver
to pry the Top Shield upward off the elliptical.
Next, look into the access opening and locate the
Reed Switch (58). Rotate the Pulley (66) until a
Magnet (41) is aligned with the Reed Switch. Note: For
clarity, the shields are shown removed in the drawing
below.
Next, loosen, but do not remove, the two indicated
M4 x 16mm Screws (61). Slide the Reed Switch (58)
slightly toward or away from the Magnet (41). Then,
retighten the M4 x 16mm Screws.
Plug in the power adapter and rotate the pulley for a
moment. Repeat these actions until the console dis-
plays correct feedback.
When the reed switch is correctly adjusted, unplug
the power adapter and reattach the top shield and the
large storage foot. Then, plug in the power adapter.
37
27
66
58
41
61