HealthRider H95e Elliptical English Manual - Page 20

Maintenance And Troubleshooting

Page 20 highlights

MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damaging the console, keep liquids away from the console and keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, first unplug the power cord. Using a flat screwdriver, release the tabs on the Access Cover (20) and pull the Access Cover upward off the elliptical. If the console does not turn on, make sure that the power cord is fully plugged in. 20 If the console does not display your heart rate when you hold the handgrip heart rate monitor, or if the displayed heart rate appears to be too high or too low, see step 5 on page 17. HOW TO CALIBRATE THE RAMP If the ramp is not functioning properly, the ramp may need to be calibrated. To calibrate the ramp, press and hold the Target Toning Workouts button for several seconds until the calibration mode appears in the display. Press the Target Toning Workouts once. The ramp calibration instructions will appear in the display. Press the One Touch Ramp increase or decrease button to calibrate the ramp. The ramp will move upward and downward as it calibrates. Next, look into the access opening and locate the Reed Switch (69). Rotate the Large Pulley (74) until a Pulley Magnet (75) is aligned with the Reed Switch. 74 75 When the ramp stops moving, the ramp is calibrated. Then, press the Target Toning Workouts button repeatedly to exit the calibration mode. 69 106 Next, loosen, but do not remove, the indicated M4 x 16mm Screw (106). Slide the Reed Switch (69) slightly toward or away from the Pulley Magnet (75). Then, retighten the M4 x 16mm Screw. Plug in the power cord and rotate the large pulley for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, reattach the access cover. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

20
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid dam-
aging the console, keep liquids away from the
console and keep the console out of direct sun-
light.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low,
see step 5 on page 17.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, press
and hold the Target Toning Workouts button for sev-
eral seconds until the calibration mode appears in the
display.
Press the Target Toning Workouts once. The ramp
calibration instructions will appear in the display. Press
the One Touch Ramp increase or decrease button to
calibrate the ramp. The ramp will move upward and
downward as it calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the Target Toning Workouts button
repeatedly to exit the calibration mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed switch, first unplug the power
cord. Using a flat screwdriver, release the tabs on the
Access Cover (20) and pull the Access Cover upward
off the elliptical.
Next, look into the access opening and locate the
Reed Switch (69). Rotate the Large Pulley (74) until a
Pulley Magnet (75) is aligned with the Reed Switch.
Next, loosen, but do not remove, the indicated M4 x
16mm Screw (106). Slide the Reed Switch (69) slightly
toward or away from the Pulley Magnet (75). Then,
retighten the M4 x 16mm Screw.
Plug in the power cord and rotate the large pulley for
a moment. Repeat these actions until the console
displays correct feedback. When the reed switch is
correctly adjusted, reattach the access cover.
MAINTENANCE AND TROUBLESHOOTING
20
74
69
106
75