HP 8530p Intel Centrino 2 with vProâ„¢ technology Setup and C - Page 13

Default Setting, Enabled, Recommended Setting, Current Date and Time in GMT UTC

Page 13 highlights

so counting dashes PIDs are 9 characters and PPS are 40 characters. They must be generated by an S&CS. The Admin Password, PID, and PPS can be populated by the use of a pre-generated USB key generated by the ISV Management Console. 20) Skip Un-Provision. For AMT 2.x, this option is to return the system to factory defaults. For AMT 4.x, the unprovision option in MEBx will not reset the system to factory default. See the Return to Default section for more information on unprovisioning. 21) Check SOL/IDE-R. a. A message window telling the user that the system resets after configuration will appear. i. Select Y. b. Username and Password Default Setting : Enabled Recommended Setting : Enabled i. Select Enabled. This option allows users and passwords to be added from the WebGUI. If it is disabled, then only the administrator has MEBx remote access. c. Serial Over LAN Default Setting : Enabled Recommended Setting : Enabled i. Select Enabled. d. IDE Redirection Default Setting : Enabled Recommended Setting : Enabled i. Select Enabled. 22) Skip Secure Firmware Update. Important Note: You may have to use the arrow keys to scroll down and see the following options. 23) Go into Set PRTC. Default Setting : None Recommended Setting : Current Date and Time in GMT (UTC) This option sets the PRTC (Protected Real Time Clock). It is used with TLS mutual authentication which checks for the client certificate for expiration based on its PRTC. PRTC has a valid date range of 1/1/2004 to 1/4/2021. 24) Skip Idle Timeout. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

13
so counting dashes PIDs are 9 characters and PPS are 40 characters. They must be
generated by an S&CS.
The Admin Password, PID, and PPS can be populated by the use of a pre-generated USB key
generated by the ISV Management Console.
20)
Skip Un-Provision.
For AMT 2.x, this option is to return the system to factory defaults.
For AMT 4.x, the
unprovision option in MEBx will not reset the system to factory default.
See the Return to
Default section for more information on unprovisioning.
21)
Check SOL/IDE-R.
a.
A message window telling the user that the system resets after configuration will
appear.
i.
Select Y.
b.
Username and Password
Default Setting
: Enabled
Recommended Setting
: Enabled
i.
Select Enabled.
This option allows users and passwords to be added from the WebGUI. If it is
disabled, then only the administrator has MEBx remote access.
c.
Serial Over LAN
Default Setting
: Enabled
Recommended Setting
: Enabled
i.
Select Enabled.
d.
IDE Redirection
Default Setting
: Enabled
Recommended Setting
: Enabled
i.
Select Enabled.
22)
Skip Secure Firmware Update.
Important Note:
You may have to use the arrow keys to scroll down and see the following
options.
23)
Go into Set PRTC.
Default Setting
: None
Recommended Setting
: Current Date and Time in GMT (UTC)
This option sets the PRTC (Protected Real Time Clock). It is used with TLS mutual authentication
which checks for the client certificate for expiration based on its PRTC.
PRTC has a valid date range of 1/1/2004 to 1/4/2021.
24)
Skip Idle Timeout.