HP-UX Installation Interpreting Hardware Paths 3. HP Fibre Channel Mass Storage installation is verified if the ioscan output lists all mass storage devices attached to the adapter. If any attached devices are not listed or appear as UNCLAIMED, see the Troubleshooting and Maintenance chapter of the HP Fibre Channel Adapters Support Guide. Interpreting Hardware Paths The following illustration is the Fibre Channel hardware path format: Figure 1-2 Example of a Hardware Path for a Public Loop Device Adapter Domain Area Port Bus Target LUN 0/1/2/0.1.19.255.15.4.0 Figure 1-3 Example of a Hardware Path for a Direct Fabric Attach Device Adapter Domain Area Port Bus Target LUN 0/1/2/0.1.19.255.0.0.0 Figure 1-4 Example of a Hardware Path for a Private Loop Device Adapter Domain Area Port Bus Target LUN 0/1/2/0.8.0.255.0.1.0 Each field in the hardware path is described below: Field Value Information Fibre Channel Topology of HBA Fabric Topologies such as Public Loop and Direct Fabric Attach Private Loop Adapter This is the hardware path of the Fibre Channel adapter through which the LUN is seen. In the case of multi-port adapters, this field describes a specific port on the adapter. Chapter 1 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

HP-UX Installation
Interpreting Hardware Paths
Chapter 1
13
3. HP Fibre Channel Mass Storage installation is verified if the ioscan output lists all mass storage devices
attached to the adapter. If any attached devices are not listed or appear as UNCLAIMED, see the
Troubleshooting and Maintenance chapter of the HP Fibre Channel Adapters Support Guide.
Interpreting Hardware Paths
The following illustration is the Fibre Channel hardware path format:
Figure 1-2
Example of a Hardware Path for a Public Loop Device
Figure 1-3
Example of a Hardware Path for a Direct Fabric Attach Device
Figure 1-4
Example of a Hardware Path for a Private Loop Device
Each field in the hardware path is described below:
Field
Value Information
Fibre Channel Topology of HBA
Fabric Topologies such as Public
Loop and Direct Fabric Attach
Private Loop
Adapter
This is the hardware path of the Fibre Channel adapter through which the LUN is seen.
In the case of multi-port adapters, this field describes a specific port on the adapter.
Adapter
Area
Port
Bus
Target LUN
Domain
0/1/2/0.1.19.255.15.4.0
Adapter
Area
Port
Bus
Target LUN
Domain
0/1/2/0.1.19.255.0.0.0
Adapter
Area
Port
Bus
Target LUN
Domain
0/1/2/0.8.0.255.0.1.0