HP Armada 1500 Compaq Armada 1500 Family of Personal Computers Maintenance and - Page 42
Table 3-12, Audio Test Error Codes, Error, Description, Recommended Action
View all HP Armada 1500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Table 3-11 Continued Error Code Description Recommended Action 2419-xx ECG/VGC ROM checksum test failed The following steps apply to error codes 2403-xx through 2456-xx: 2421-xx ECG/VGC 640 × 200 graphics mode test 1. Run Computer Setup. failed 2423-xx ECG/VGC 640 × 350 16 color set test failed 2. Disconnect external monitor and test with internal LCD display. 2423-xx ECG/VGC 640 × 350 64 color set test failed 3. Replace the display assembly and retest. 2424-xx ECG/VGC monochrome text mode test failed 4. Replace the system board and retest. 2425-xx ECG/VGC monochrome graphics mode test failed 2431-xx 640 × 480 graphics test failure 2433-xx 320 × 200 graphics (256 color mode) test failure 2448-xx Advanced VGA Controller test failed 2451-xx 133-column Advanced VGA test failed 2456-xx Advanced VGA 256 Color test failed 2458-xx Advanced VGA BitBLT test The following applies to error codes 2458-xx through 2480-xx: 2468-xx Advanced VGA DAC test Replace the system board and retest. 2477-xx Advanced VGA data path test 2478-xx Advanced VGA BitBLT test 2480-xx Advanced VGA Linedraw test Table 3-12 Audio Test Error Codes Error Code Description Recommended Action 3206-xx Audio System Internal Error Replace the audio board and retest. Troubleshooting 3-15