Specifications Environmental specifications Specification Temperature range* Operating Shipping Storage Maximum wet bulb temperature Relative humidity (noncondensing)** Operating Shipping Storage Value 10°C to 35°C (50°F to 95°F) -40°C to 60°C (-40°F to 140°F) -20°C to 60°C (-4°F to 140°F) 30°C (86°F) 10% to 90% 10% to 90% 10% to 95% * All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia. ** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. Server blade specifications Specification Height Depth Width Weight (maximum) Value 36.60 cm (14.42 in) 50.90 cm (20.06 in) 5.14 cm (2.03 in) 10.34 kg (22.80 lb) Specifications 84
![](/manual_guide/products/hewlettpackard-bl685c-hp-proliant-bl685c-generation-5-server-blade-user-guide-b66a8ef/84.png)