HP Brocade 8/12c Brocade Network Advisor Documentation Updates v11.1.x (53-100 - Page 158
Table 298, Switch_port_performance
![]() |
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 158 highlights
E Database tables and fields TABLE 297 SWITCH_PORT_PERFORMANCE (Continued) Field Definition Format Size RX_UTILIZATION LINK_FAILURE TX_LINK_RESETS RX_LINK_RESETS SYNC_LOSSES SIGNAL_LOSSES SEQUENCE_ERRORS INVALID_TRANSMISSIONS CRC_ERRORS LAST_UPDATE_TIME 'The computed value of RX based on speed of port double precision Count of link failures. This count is part of the Link double Error Status Block (LESB). (FC-PH 29.8). Note, this is precision a Fibre Channel only stat Count of Link resets. This is the number of LRs received. Note, this is a Fibre Channel only stat double precision Count of Link resets. This is the number LRs transmitted. Note, this is a Fibre Channel only stat double precision Count of instances of synchronization loss detected at port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat. double precision Count of instances of signal loss detected at port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat double precision Count of primitive sequence protocol errors detected at this port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat double precision Count of invalid transmission words received at this port. This count is part of the Link Error Status Block (LESB). FC-PH 29.8). Note, this is a Fibre Channel only stat double precision Count of frames received with invalid CRC. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Loop ports should not count CRC errors passing through when monitoring. Note, this is a Fibre Channel only stat.' double precision Time when this stats record was updated timestamp TABLE 298 SWITCH_TE_PORT_PERFORMANCE Field Definition Format Size PORT_ID SWITCH_ID TX Primary key of the Switch Port Primary key of Virtual Switch which this port is present The number of octets or bytes that have been transmitted by this port. One second periodic polling of the port. This value is saved and compared with the next polled value to compute net throughput. Note, for Fibre Channel, ordered sets are not included in the count. int int double precision 150 Brocade Network Advisor Documentation Updates 53-1002363-02
![](/manual_guide/products/hewlettpackard-brocade-812c-brocade-network-advisor-documentation-updates-v111x-53100236303-2011-4c13200/158.png)