HP C5726A HP Surestore DLT Internal/External Tape Drive User's Guide - Page 68

Interface Specification, Environmental Specification, Vibration and Shock Tolerance

Page 68 highlights

Product Specifications and Ordering Information Product Specification Interface Specification HP SureStore DLT 40 Narrow single-ended SCSI-2 (8-bit wide data transfers : with parity) HP SureStore DLT 70 Fast, wide single-ended SCSI-2 (16-bit wide data : transfers with parity) HP SureStore DLT 80 Ultra-wide SCSI-2 (16-bit wide data transfers), which can : be used with both LVD (low-voltage differential) and single-ended host bus adapters. Environmental Specification See page 4-5 for advice on using and storing cartridges. Operating Limits Temperature: 10°C to 40° C (50°F to 104°F) Humidity: 20% to 80% non-condensing Altitude: 0 m to 9 km (0 to 30,000 ft) Non-operating Limits Temperature: −40°C to 66° C (−40°F to 151°F) Humidity: 10% to 95% non-condensing Altitude: 0 m to 15 km (0 to 50,000 ft) Cooling (HP SureStore DLT 40i, 70i and 80i only) Requires air flow of 0.635 m/s (125 linear feet per minute). The measurement is taken at the front grill under the handle. Air flow should be from front to back. Vibration and Shock Tolerance Operating Vibration Vibration Type Sine Frequency Range: 5-500-5 Hz Acceleration Level: 0.25g 0.010" DA Application: X, Y and Z axes Sweep Upward and downward 22 to 500 Hz 5 to 22 Hz (crossover) Sweep rate: 1 octave per minute A-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93

Product Specifications and Ordering Information
Product Specification
A-3
Interface Specification
Environmental Specification
See page 4-5 for advice on using and storing cartridges.
Operating Limits
Non-operating Limits
Cooling (HP SureStore DLT 40i, 70i and 80i only)
Requires air flow of 0.635 m/s (125 linear feet per minute). The
measurement is taken at the front grill under the handle. Air flow should
be from front to back.
Vibration and Shock Tolerance
Operating Vibration
HP SureStore DLT 40
:
Narrow single-ended SCSI-2 (8-bit wide data transfers
with parity)
HP SureStore DLT 70
:
Fast, wide single-ended SCSI-2 (16-bit wide data
transfers with parity)
HP SureStore DLT 80
:
Ultra-wide SCSI-2 (16-bit wide data transfers), which can
be used with both LVD (low-voltage differential) and
single-ended host bus adapters.
Temperature:
10
°
C to 40
°
C (50
°
F to 104
°
F)
Humidity:
20% to 80% non-condensing
Altitude:
0 m to 9 km (0 to 30,000 ft)
Temperature:
40
°
C to 66
°
C (
40
°
F to 151
°
F)
Humidity:
10% to 95% non-condensing
Altitude:
0 m to 15 km (0 to 50,000 ft)
Vibration Type
Sine
Sweep
Frequency Range:
5
500
5 Hz
Upward and downward
Acceleration Level:
0.25g
0.010
DA
22 to 500 Hz
5 to 22 Hz (crossover)
Application:
X, Y and Z axes
Sweep rate: 1 octave per minute