HP Carrier-grade cc2300 UserÆs Guide and Technical UserÆs Gu - Page 64

Equipment Rack Precautions

Page 64 highlights

HP cc3300 Carrier Grade Server Product Guide Equipment Rack Precautions WARNING ANCHOR THE EQUIPMENT RACK: The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The equipment rack must be installed according to the manufacturer's instructions. You must also consider the weight of any other device installed in the rack. MAIN AC POWER DISCONNECT: You are responsible for installing an AC power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must be labeled as controlling power to the entire unit, not just to the server(s). GROUNDING THE RACK INSTALLATION: To avoid the potential for an electrical shock hazard, you must include a third wire safety grounding conductor with the rack installation. If server power cords are plugged into AC outlets that are part of the rack, then you must provide proper grounding for the rack itself. If server power cords are plugged into wall AC outlets, the safety grounding conductor in each power cord provides proper grounding only for the server. You must provide additional, proper grounding for the rack and other devices installed in it. OVER CURRENT PROTECTION: The server is designed for an AC line voltage source with up to 20 amperes of over current protection. If the power system for the equipment rack is installed on a branch circuit with more than 20 amperes of protection, you must provide supplemental protection for the server. If more than one server is installed in the rack, the power source for each server must be from a separate branch circuit. CAUTION Temperature: The operating temperature of the server, when installed in an equipment rack, must not go below 5 °C (41 °F) or rise above 40 °C (104 °F). Extreme fluctuations in temperature can cause a variety of problems in your server. Ventilation: The equipment rack must provide sufficient airflow to the front of the server to maintain proper cooling. The rack must also include ventilation sufficient to exhaust a maximum of 1023 BTU's per hour for the server. The rack selected and the ventilation provided must be suitable to the environment in which the server will be used. 64 Technical User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133

HP cc3300 Carrier Grade Server Product Guide
64
Technical User’s Guide
Equipment Rack Precautions
WARNING
ANCHOR THE EQUIPMENT RACK:
The equipment rack must be
anchored to an unmovable support to prevent it from falling over when
one or more servers are extended in front of it on slide assemblies.
The
equipment rack must be installed according to the manufacturer's
instructions.
You must also consider the weight of any other device
installed in the rack.
MAIN AC POWER DISCONNECT:
You are responsible for installing
an AC power disconnect for the entire rack unit.
This main disconnect
must be readily accessible, and it must be labeled as controlling power to
the entire unit, not just to the server(s).
GROUNDING THE RACK INSTALLATION:
To avoid the potential
for an electrical shock hazard, you must include a third wire safety
grounding conductor with the rack installation.
If server power cords
are plugged into AC outlets that are part of the rack, then you must
provide proper grounding for the rack itself.
If server power cords are
plugged into wall AC outlets, the safety grounding conductor in each
power cord provides proper grounding only for the server.
You must
provide additional, proper grounding for the rack and other devices
installed in it.
OVER CURRENT PROTECTION:
The server is designed for an
AC line voltage source with up to 20 amperes of over current protection.
If the power system for the equipment rack is installed on a branch
circuit with more than 20 amperes of protection, you must provide
supplemental protection for the server.
If more than one server is
installed in the rack, the power source for each server must be from a
separate branch circuit.
CAUTION
Temperature:
The operating temperature of the server, when installed in an
equipment rack, must not go below 5 °C (41 °F) or rise above 40 °C
(104 °F).
Extreme fluctuations in temperature can cause a variety of
problems in your server.
Ventilation:
The equipment rack must provide sufficient airflow to the front
of the server to maintain proper cooling.
The rack must also include
ventilation sufficient to exhaust a maximum of 1023 BTU's per hour for the
server.
The rack selected and the ventilation provided must be suitable to the
environment in which the server will be used.