HP D2200sb Serial Attached SCSI technology, 3rd edition - Page 5

Examples of differential signaling, Physical link rates per direction, 5 Gb/s, SAS-1, SATA Revision

Page 5 highlights

Differential signaling reduces the effects of capacitance, inductance, and noise experienced by parallel SCSI at higher speeds. In differential signaling, the positive signal minus the negative signal equals 1500-900 = 600mV or 900-1500 = - 600mV (Figure 2). SAS communication operates in full duplex mode, which means that each PHY can send and receive information simultaneously over the two wire pairs. Figure 2. Examples of differential signaling Table 2 lists the physical link rates for SAS and SATA. Table 2. Physical link rates per direction Physical link rate 1.5 Gb/s 3 Gb/s 6 Gb/s Generation Bandwidth for a 1x connection SAS-1, SAS-1.1, SATA Revision 150 MB/s 1.0 SAS-1, SAS-1.1, SATA Revision 300 MB/s 2.0 SAS-2, SAS-2.1, SATA Revision 600 MB/s 3.0 4x bandwidth 600 MB/s 1200 MB/s 2400 MB/s 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Differential signaling reduces the effects of capacitance, inductance, and noise experienced by
parallel SCSI at higher speeds. In differential signaling, the positive signal minus the negative signal
equals 1500–900 = 600mV or 900–1500 = – 600mV (Figure 2). SAS communication operates in
full duplex mode, which means that each PHY can send and receive information simultaneously over
the two wire pairs.
Figure 2.
Examples of differential signaling
Table 2 lists the physical link rates for SAS and SATA.
Table 2.
Physical link rates per direction
Physical link rate
Generation
Bandwidth for a 1x
connection
4x bandwidth
1.5 Gb/s
SAS-1, SAS-1.1, SATA Revision
1.0
150 MB/s
600 MB/s
3 Gb/s
SAS-1, SAS-1.1, SATA Revision
2.0
300 MB/s
1200 MB/s
6 Gb/s
SAS-2, SAS-2.1, SATA Revision
3.0
600 MB/s
2400 MB/s
5