HP EVA P6550 HP Controller Enclosure Battery Replacement Instructions (5697-13 - Page 1

HP EVA P6550 Manual

Page 1 highlights

HP Controller Enclosure Battery Replacement Instructions © Copyright 2012 Hewlett-Packard Development Company, L.P. Printed in Puerto Rico HP Part Number: 5697-1348 Published: June 2012 Edition: 2 *5697-1348* About this document For the latest documentation, go to http:// www.hp.com/support/manuals, and select your product. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. WARRANTY STATEMENT: To obtain a copy of the warranty for this product, see the warranty information website: http://www.hp.com/go/storagewarranty Before you begin XCS version 11001000 and later supports HP P6350/P6550 EVAs with 2- or 4-GB DIMMs and large capacity batteries. Upgrade kits are available that include batteries, DIMMs, and an ABM. If you are upgrading an HP P6300 to P6350 or an HP P6500 to P6550, HP recommends that you install an upgrade kit. Because you must install the upgrade components in a specific order and off line, follow the procedure in HP P6000 EVA Upgrade Instructions - P6300 to P6350 or P6500 to P6550. There are three battery models. The battery module faceplate identifies the model. • A P6300 or P6500 EVA can use AG637-63601, QK715-63601, or QK717-63601 batteries. • A P6350 EVA can use QK715-63601 or QK717-63601 batteries. • A P6550 EVA can use QK717-63601 batteries only. Observe the following precautions when replacing the battery module. CAUTION: Removing a battery module significantly changes the air flow within the enclosure. Both modules must be installed for the enclosure to cool properly. If a single battery module fails, leave it in place in the enclosure until a new module is available to install. Page 1

  • 1
  • 2
  • 3

HP Controller Enclosure
Battery Replacement
Instructions
© Copyright 2012 Hewlett-Packard Development Company, L.P.
Printed in Puerto Rico
*5697-1348*
HP Part Number: 5697-1348
Published: June 2012
Edition: 2
About this document
For the latest documentation, go to
h
t
tp://
w
w
w
.hp
.co
m/su
ppo
r
t/man
uals
, and select your
product.
The information contained herein is subject to change
without notice. The only warranties for HP products
and services are set forth in the express warranty
statements accompanying such products and services.
Nothing herein should be construed as constituting an
additional warranty. HP shall not be liable for technical
or editorial errors or omissions contained herein.
WARRANTY STATEMENT:
To obtain a copy of the warranty for this product, see
the warranty information website:
h
t
tp://w
w
w
.hp
.co
m/go/s
t
o
r
age
w
ar
r
an
t
y
Before you begin
XCS version 11001000 and later supports HP
P6350/P6550 EVAs with 2- or 4-GB DIMMs and large
capacity batteries. Upgrade kits are available that
include batteries, DIMMs, and an ABM. If you are
upgrading an HP P6300 to P6350 or an HP P6500
to P6550, HP recommends that you install an upgrade
kit. Because you must install the upgrade components
in a specific order and off line, follow the procedure
in
HP P6000 EVA Upgrade Instructions — P6300 to
P6350 or P6500 to P6550
.
There are three battery models. The battery module
faceplate identifies the model.
A P6300 or P6500 EVA can use AG637-63601,
QK715-63601, or QK717-63601 batteries.
A P6350 EVA can use QK715-63601 or
QK717-63601 batteries.
A P6550 EVA can use QK717-63601 batteries
only.
Observe the following precautions when replacing the
battery module.
CAUTION:
Removing a battery module
significantly changes the air flow within the
enclosure. Both modules must be installed for
the enclosure to cool properly. If a single battery
module fails, leave it in place in the enclosure
until a new module is available to install.