HP Indigo W7250 Preventive Maintenance -- CA393-00660 Rev 08 - Page 14

Print Care Center > Maintenance Explorer > Maintenance > Customer Engineer 12M Imp

Page 14 highlights

Component Procedure ● Clean overflow waste tank. ● Clean the water separator by draining. Utility cabinet ● Check the recycling system. Remove, clean and restart if necessary. ● Clean the UC condenser and damper. ● Check for water condensation in the U.C, wipe and dry the U.C. If needed, perform the procedure in Water contamination troubleshooting (CA393-05510). ● Check the water inlet filter element, and refill the water circuit (replace if needed). ● With the chiller powered down and the press disconnected (main power off), clean the condenser with a blast of compressed air, from inside toward the outside. Chiller ● Clean the housing inside and outside, eliminating dust, especially on the water pump rack. ● Verify that the water temperature indicated on the control thermostat is approximately at the set point at 0.5°C. ● Check the state of the water filter. If the pressure drop exceeds 1 bar (10 psi), change the filter element. ILD ● If ILD is installed, perform full color calibration and check using a CATP that all colors are in target. If not, proceed to TS (if needed perform full ILD calibration). SPM ● If SPM is installed, perform full color calibration and check using a CATP that all colors are in target. If not, proceed to TS. Reset 12M IMP Counter ● Select Print Care Center > Maintenance Explorer > Maintenance > Customer Engineer 12M Imp Maintenance Routine. (Only for HP ● Click Next. Indigo WS6000 Series Digital Presses with ● Select Click Finish to confirm compilation of Customer Engineer 12M Imp maintenance. press software v15.0 I-Fix 1 and above) ● Click Finish. 12 Chapter 2 Procedures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Component
Procedure
Utility cabinet
Clean overflow waste tank.
Clean the water separator by draining.
Check the recycling system. Remove, clean and restart if necessary.
Clean the UC condenser and damper.
Check for water condensation in the U.C, wipe and dry the U.C. If needed, perform the procedure in
Water contamination troubleshooting
(CA393-05510).
Chiller
Check the water inlet filter element, and refill the water circuit (replace if needed).
With the chiller powered down and the press disconnected (main power off), clean the condenser with a
blast of compressed air, from inside toward the outside.
Clean the housing inside and outside, eliminating dust, especially on the water pump rack.
Verify that the water temperature indicated on the control thermostat is approximately at the set point
at 0.5°C.
Check the state of the water filter. If the pressure drop exceeds 1 bar (10 psi), change the filter element.
ILD
If ILD is installed, perform full color calibration and check using a CATP that all colors are in target. If not,
proceed to TS (if needed perform full ILD calibration).
SPM
If SPM is installed, perform full color calibration and check using a CATP that all colors are in target. If
not, proceed to TS.
Reset 12M IMP
Counter
(Only for HP
Indigo WS6000 Series
Digital Presses with
press software v15.0
I-Fix 1 and above)
Select
Print Care Center > Maintenance Explorer > Maintenance > Customer Engineer 12M Imp
Maintenance Routine
.
Click
Next
.
Select
Click Finish to confirm compilation of Customer Engineer 12M Imp maintenance
.
Click
Finish
.
12
Chapter 2
Procedures