Attempt to update the PD PDT with OLA Cell failed Probable Cause: Unable to add
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
Event ID Event Severity Event Description 8263 Warning Partition attempted to OLA a cell that was not fully ready for the operation. Probable Cause: OLA cell hung during its part of the OLA process. Consult chassis codes from the OLA cell to determine what happened. A secondary problem here is that the root cell attempted to OLA a cell that could not have sent the Ready to OLA command (since it hung). This would indicate a failure on the OS side to correctly handle OLA-associated interrupts. Recommended Action: Collect IPMI events and contact HP Customer Support for assistance. SNMP Trap: hpevtBootOlaCellDidNotReachRendezvous - 8263 in HPIFPTRAP.MIB. 8264 Warning Partition attempted to OLA a cell still waiting at BIB. Probable Cause: Interrupt problem. Root cell should not attempt to OLA a cell until that cell send the Ready to OLA message, which a cell at BIB cannot have done. Recommended Action: Attempt the OLA operation again. If failure continues, gather IPMI event logs and contact HP Customer Support for assistance. SNMP Trap: hpevtBootOlaCellStillAtBib - 8264 in HPIFPTRAP.MIB. 8265 Warning Partition attempted to OLA a cell in an unexpected Cell state Probable Cause: OLA cell has reached unknown state after sending Ready to OLA command, or OLA was attempted on cell that was not ready to OLA. Recommended Action: Attempt the OLA operation again, or collect IPMI event logs and contact HP Customer Support for assistance. SNMP Trap: hpevtBootOlaCellUnexpectedCellState - 8265 in HPIFPTRAP.MIB. 8267 Warning OLA cell was unable to reach some cell(s) in the alive set Probable Cause: Bad fabric link between OLA cell and cells already in the partition. Recommended Action: Fabric links between cells may have failed. Contact HP Customer Support for assistance. SNMP Trap: hpevtBootOlaCellCantReachAliveCells - 8267 in HPIFPTRAP.MIB. 8269 Warning CPUs of different maximum core frequencies are installed Probable Cause: CPU's of mixed maximum core frequencies are installed. Recommended Action: Install CPU's with the same speed and cache size. SNMP Trap: hpevtBootMixedCpuCoreFreqInstalled - 8269 in HPIFPTRAP.MIB. 8271 Error The RVL CC-Togo link initialization workaround (PS221) failed Probable Cause: Hardware link initialization failed. Recommended Action: Contact HP support. Reset cell. SNMP Trap: hpevtXinInitIntermittentFailure - 8271 in HPIFPTRAP.MIB. 8643 Warning PDC failed clearing the OLA steering bit in the Dillon microstatus reg. Probable Cause: Probably something wrong with the cell hardware. Recommended Action: Try OLAing a different cell. Contact HP Support personnel to troubleshoot the problem. SNMP Trap: hpevtPdhErrClearOlaSteeringBit - 8643 in HPIFPTRAP.MIB. 8645 Error The attempt to update the PD Addr Map to include OLA cell failed. Probable Cause: System FW was unable to add the OLA cell's memory to the PD address map. Error writing to PDH space. Likely cell board error Recommended Action: Collect IPMI event logs and contact HP Support. SNMP Trap: hpevtBootOlaFailedUpdatePdAddrMap - 8645 in HPIFPTRAP.MIB. 8646 Error Attempt to update the PD PDT with OLA Cell failed Probable Cause: Unable to add OLA cell's PDT to the partition PDT. Error accessing PDH space. Check fabric connection between OLA cell and core cell. Recommended Action: Gather IPMI event logs and contact HP Support. SNMP Trap: hpevtBootOlaFailedUpdatePdPdt - 8646 in HPIFPTRAP.MIB. 8647 Warning Attempt to update the cell map to include the OLA Cell failed Probable Cause: Unable to write registers on the CC. Check cell board and system fabric. Recommended Action: Collect IPMI events and contact HP Support. SNMP Trap: hpevtBootOlaFailedUpdateCellMap - 8647 in HPIFPTRAP.MIB. 8648 Error Fabric Discovery could not initialize the local cell's XBC link Probable Cause: CC to XBC link init failure. Recommended Action: check CC, XBC, reset cell, reset backplane SNMP Trap: hpevtFabricCc2XbcLinkInitFailed - 8648 in HPIFPTRAP.MIB. 8652 Error Internal firmware programming error Probable Cause: Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. SNMP Trap: hpevtFwVirtualMappingError - 8652 in HPIFPTRAP.MIB. Platform Agent Events 51