HP Integrity rx2660 Windows Integrity Management Agents Reference - Page 43
IO Fan Module as soon as possible following the IO Fan Module Remove and Replace - firmware update
![]() |
View all HP Integrity rx2660 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Event ID Event Severity Event Description 7824 Warning The BPSs for the cabinet are illegally configured. Data Byte 3 = PDCA number. Probable Cause: The BPS are installed in an illegal configuration. Recommended Action: Re-configure the BPS in a manner consistent with the explanation in the Problem Description statement SNMP Trap: hpevtIllegalBpsCfgOrPhaseFlt - 7824 in HPIFPTRAP.MIB. 7825 Warning BPS ID received from installed Bulk Power Supply was unknown Probable Cause: The designated power supply is responding with an illegal BPS ID. It could be a faulty supply, a different revision, or a wrong supply in the wrong box. Recommended Action: Replace this Bulk Power Supply with a proper one. SNMP Trap: hpevtIllegalBpsid - 7825 in HPIFPTRAP.MIB. 7827 Error Ambient Air Sensor Overtemp Warning Probable Cause: Room Temperature has risen to a critical level. Recommended Action: Shutdown and power off the system. Correct air temperature problem. SNMP Trap: hpevtInletOvertempHi - 7827 in HPIFPTRAP.MIB. 7828 Warning Ambient Air Sensor Overtemp Warning Probable Cause: Room Temperature is rising or falling. Recommended Action: Check the error log's previous entries within a logical time frame. If temperature is rising, prepare for system shutdown. If temperature is dropping, then problem is probably resolved. SNMP Trap: hpevtInletOvertempLo - 7828 in HPIFPTRAP.MIB. 7829 Error Ambient Air Sensor Overtemp Warning Probable Cause: Room Temperature is rising or falling. Recommended Action: Check the error log's previous entries within a logical time frame. If temperature is rising, prepare for system shutdown. If temperature is dropping, then problem is probably resolved. SNMP Trap: hpevtInletOvertempMid - 7829 in HPIFPTRAP.MIB. 7836 Warning IO Fan Failed Probable Cause: IO Cooling Fan Failed Recommended Action: Replace IO Fan Module as soon as possible following the IO Fan Module Remove and Replace Procedures. SNMP Trap: hpevtIofanFail - 7836 in HPIFPTRAP.MIB. 7842 Warning Cabinet Power System is in overload. Probable Cause: A Bulk Power Supply has failed, or, entities were added. Look for one or more BPS_Fail Chassis Codes preceding this one for the actual failures. This code is a warning of possible cabinet unreliability. Recommended Action: Contact HP Support personnel to troubleshoot the problem. SNMP Trap: hpevtPowerOverload - 7842 in HPIFPTRAP.MIB. 7845 Error Cabinet Shutdown - Insufficient Blowers Probable Cause: One blower has failed creating condition N. Before condition N was corrected, another blower in the same cabinet was declared failed. This created the illegal condition of N-1. Recommended Action: Contact HP Support personnel to troubleshoot the problem SNMP Trap: hpevtShutdownBlowr - 7845 in HPIFPTRAP.MIB. 7846 Error Cabinet Shutdown - Insufficient IO Fans Probable Cause: One IO fan has failed creating condition N. Before condition N was corrected, another IO fan in the same cabinet failed. This created the illegal condition of N-1. Recommended Action: Contact HP Support personnel to troubleshoot the problem SNMP Trap: hpevtShutdownIofan - 7846 in HPIFPTRAP.MIB. 7849 Warning IO Expansion Utility Cabinet Fan Failed Probable Cause: IO Expansion Utility Fan or Fan sensor failure PM failure Recommended Action: Contact HP Support personnel to troubleshoot the problem SNMP Trap: hpevtXucFanFail - 7849 in HPIFPTRAP.MIB. 7855 Error Watchdog Timer Expired Probable Cause: CLU has been reset after a firmware update. Recommended Action: No action is required. SNMP Trap: hpevtCluWatchdogReset - 7855 in HPIFPTRAP.MIB. Platform Agent Events 43
![](/manual_guide/products/hewlettpackard-integrity-rx2660-windows-integrity-management-agents-reference-e658e5f/43.png)