HP Integrity rx2660 Windows Integrity Management Agents Reference - Page 59
Table #2, Event ID numbers 9, 000 through 12
View all HP Integrity rx2660 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Event ID Event Severity Event Description 8983 Error A fabric walk failed while updating the cell state Probable Cause: Look for adjacent chassis codes to determine the cause of FabricWalk failure. Check the backplane and fabric connectivity. Contact the HP Support Personnel for further troubleshooting. SNMP Trap: hpevtBootSetCellStateFabricFailure - 8983 in HPIFPTRAP.MIB. 8984 Error Could not reset the cell due to failure updating cell state Probable Cause: Most likely a failure on the fabric or on the CC. Fabric failures should produce additional chassis codes. If no additional chassis codes indicate the cause of the failure, then contact the HP Support Personnel for further troubleshooting. SNMP Trap: hpevtBootResetCellStateFailure - 8984 in HPIFPTRAP.MIB. Table #2 - Event ID numbers 9,000 through 12,627 Event ID Event Severity Event Description 9000 Warning DRAM failure on DIMM XX, deallocate rank Probable Cause: SFW detected a failing DIMM Recommended Action: Replace the DIMM flagged by SFW SNMP Trap: hpevtMemChipspareDeallocRank - 9000 in HPIFPTRAP.MIB. 9019 Error System Clocks are not valid Probable Cause: The Cell board has a problem. Either the Real Time Clock is not working properly or the system is not being clocked at the value it thinks it is. SNMP Trap: hpevtClockFreqError - 9019 in HPIFPTRAP.MIB. 9020 Error Cell Online Addition failed due to fabric access error Probable Cause: Fabric Access Failure, Recommended Action: Check CC to CC link. Look for additional failure chassis codes to provide more detail. SNMP Trap: hpevtFabricColaInitTraversableErr - 9020 in HPIFPTRAP.MIB. 9021 Error Fabric found a bad XBC port on a reboot. Attempting to route around it. Probable Cause: link errors. Recommended Action: Run DC Connectivity test. Check flex cables, XBCs, and CCs. SNMP Trap: hpevtFabricAttemptFocusedReroute - 9021 in HPIFPTRAP.MIB. 9022 Warning Could not access an internal firmware table while rerouting XBC port Probable Cause: Firmware Error. Recommended Action: Capture chassis codes and contact HP Support. SNMP Trap: hpevtFabricCellRerouteNinfoErr - 9022 in HPIFPTRAP.MIB. 9038 Warning Cell/Partition to be reset because PDC couldn't read PDH memory Probable Cause: Cell hardware problem like PDH memory itself, the coherency controller, the executing CPU or interaction between any of these cell components. Recommended Action: Contact HP Support to troubleshoot the cell and either fix it or replace it. SNMP Trap: hpevtBootWakeCpuIsCpuDeconfigErr - 9038 in HPIFPTRAP.MIB. 9039 Warning Cell/Partition to be reset because PDC couldn't read PDH memory Probable Cause: Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction between any of these cell components. Recommended Action: Troubleshoot the cell and either fix it or replace it. SNMP Trap: hpevtBootWakeCpuGetCountersErr - 9039 in HPIFPTRAP.MIB. 9040 Warning Cell/Partition to be reset because PDC couldn't read PDH memory Probable Cause: Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction between any of these cell components. Recommended Action: Troubleshoot the cell and either fix it or replace it. SNMP Trap: hpevtBootWakeCpuGetStructAddrErr - 9040 in HPIFPTRAP.MIB. 9041 Warning Cell/Partition to be reset because PDC couldn't read PDH memory Probable Cause: PDC bug in which PDC thinks it was unable to safely access PDH memory when maybe it really could have. Recommended Action: Upgrade PDC if this is found to be the problem and a new PDC image is available. SNMP Trap: hpevtBootCheckCpu4CompletionErr - 9041 in HPIFPTRAP.MIB. 9042 Warning Cell/Partition to be reset because PDC couldn't read PDH memory Probable Cause: PDC bug in which PDC thinks it was unable to safely access PDH memory when maybe it really could have. Recommended Action: Upgrade PDC if this is found to be the problem and a new PDC image is available. SNMP Trap: hpevtBootCheckCpuGetStructAddrErr - 9042 in HPIFPTRAP.MIB. Platform Agent Events 59