De-rate maximum dry bulb temperature 1 degree/300 meters 1000 feet above 900, meters 3000 feet.

Page 14 highlights

Operating temperature and humidity ranges may vary depending on the installed mass storage devices. High humidity levels can cause improper disk operation. Low humidity levels can aggravate static electricity problems and cause excessive wear of the disk surface. Temperature, humidity, and sound power levels are provided in Table 1-5 while minimum, maximum, and typical configurations are in Table 1-6 (page 15) and Table 1-7 (page 16). NOTE: De-rate maximum dry bulb temperature 1 degree/300 meters (1000 feet) above 900 meters 3000 feet). Table 1-5 Environmental Specifications (system processing unit with hard disk) Parameter Value Operating temperature +5˚ C to +35˚ C (+41˚ F to +95˚ F) Storage temperature - 40˚ C to +60˚ C (-40˚ F to +140˚ F) Over-temperature shutdown +38˚ C (+100˚ F) Operating humidity 20% to 80% relative (non-condensing) Storage humidity 90% relative (non-condensing) at + 65˚ C Acoustic Noise Emission (ISO 9296) Data Center Server Typical configuration (disk idle)1 LwAd = 6.8 B Sound Power Level Maximum configuration (disk idle)2 LwAd = 6.8 B Maximum configuration (disk active)3 LwAd = 7.0 B Office Friendly Server LwAd = 5.9 B LwAd = 5.9 B LwAd = 5.9 B Sound Pressure Level LpAm = 51.6 dB LpAm = 41.4 dB Altitude Operating altitude 0 to 3000 m (10,000 ft.) maximum Storage altitude 0 to 4572 m (15,000 ft.) maximum 1 Typical configuration at room temperature (25˚C). 2 Single processor, one to two SCSI hard disk drives and less than 8 GB of memory. 3 Dual processor, three SCSI hard disk drives and more than 8 GB of memory. Table 1-6 (page 15) shows the physical and environmental specifications for the Data Center server. 14 Server Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

Operating temperature and humidity ranges may vary depending on the installed mass storage
devices. High humidity levels can cause improper disk operation. Low humidity levels can
aggravate static electricity problems and cause excessive wear of the disk surface.
Temperature, humidity, and sound power levels are provided in
Table 1-5
while minimum,
maximum, and typical configurations are in
Table 1-6 (page 15)
and
Table 1-7 (page 16)
.
NOTE:
De-rate maximum dry bulb temperature 1 degree/300 meters (1000 feet) above 900
meters 3000 feet).
Table 1-5 Environmental Specifications (system processing unit with hard disk)
Value
Parameter
+5˚ C to +35˚ C (+41˚ F to +95˚ F)
Operating temperature
- 40˚ C to +60˚ C (-40˚ F to +140˚ F)
Storage temperature
+38˚ C (+100˚ F)
Over-temperature shutdown
20% to 80% relative (non-condensing)
Operating humidity
90% relative (non-condensing) at + 65˚ C
Storage humidity
Office Friendly Server
Data Center Server
Acoustic Noise Emission (ISO 9296)
LwAd = 5.9 B
LwAd = 6.8 B
Typical configuration (disk idle)
1
Sound Power Level
LwAd = 5.9 B
LwAd = 6.8 B
Maximum configuration (disk idle)
2
LwAd = 5.9 B
LwAd = 7.0 B
Maximum configuration (disk active)
3
LpAm = 41.4 dB
LpAm = 51.6 dB
Sound Pressure Level
Altitude
0 to 3000 m (10,000 ft.) maximum
Operating altitude
0 to 4572 m (15,000 ft.) maximum
Storage altitude
1
Typical configuration at room temperature (25˚C).
2
Single processor, one to two SCSI hard disk drives and less than 8 GB of memory.
3
Dual processor, three SCSI hard disk drives and more than 8 GB of memory.
Table 1-6 (page 15)
shows the physical and environmental specifications for the Data Center
server.
14
Server Specifications