Table 1-6 Physical and Environmental Specifications for the Data Center Server, Table 1-7 - weight
View all HP Integrity rx2660 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Table 1-6 Physical and Environmental Specifications for the Data Center Server Condition Weight Server Dimensions Typical Heat Release 100-127 200-240 VAC VAC Nominal Airflow Maximum Airflow @ 35 degrees C1 Server Rack Pedestal Rack Pedestal Watts Minimum 363 W Config. Maximum 782 W Config. Typical 483 W Config. Watts 363 W 782 W 483 W CFM m3/hr CFM m3/hr 21 kg - 25 kg 30 kg - 28 kg (46 - 32 37 kg 61 104 112 190 lb - 61 kg (66 lb - lb) (55 81 lb) 79 134 112 190 lb 70 lb) 61 104 112 190 D 67.3 D 69 cm W 27.6 cm W cm (with feet) W 48.3 cm 12.7 cm (w/o H 8.6 cm feet) H 50.8 (D (D 26.5 27.2 in W 10.8 in in W 19 (with feet) W 5.0 in H 3.4 in (w/o feet) H in) 20.0 in) ASHRAE Airflow cooling scheme (front to rear) Min Two 4 GB DDR2 DIMMs, n o PCIe/PCI-X public cards Class 1 config or, RAID card on private I/O slot. Max Eight 4 GB DDR2 DIMMs, three PCIe/PCI-X cards on Config public I/O slots, and RAID card in private slot. Typical Four 4 GB DDR2 DIMMs, one PCIe/PCI-X card on Config public I/O slots, and RAID card in private slot. 1 Derate maximum dry bulb temperature 1 degree / 300 meters above 900 meters. Table 1-7 (page 16) shows the physical and environmental specifications for the Office Friendly server. Physical and Environmental Specifications 15