HP Integrity rx2800 Kernel Debugging Guide - Page 15
Required plug ends and internal wiring
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Figure 1-2 Required plug ends and internal wiring Use these wiring details and one of the following pin-out tables to build the RJ45-to-DB9F converter that applies to your server model number. Table 1-3 Computer pin-outs or HP Integrity rx5670 servers RJ45 Pin 1 2 3 4 5 6 7 8 Wire Color Blue Orange Black Red Green Yellow Brown Gray (White) DB9 Female Pin 1 3 2 4 5 6 7 8 Table 1-4 Computer pin-outs for HP Integrity rx7620 and rx8620 servers RJ45 Pin 1 2 3 4 5 6 7 8 Wire Color Blue Orange Black Red Green Yellow Brown Gray (White) DB9 Female Pin 4 8 5 3 2 NC 7 6 Table 1-5 Computer pin-outs for HP Integrity Superdome/sx1000 servers RJ45 Pin 1 2 3 Wire Color Blue Orange Black DB9 Female Pin 7 5 NC Building a converter for your cable 15
Figure 1-2 Required plug ends and internal wiring
Use these wiring details and one of the following pin-out tables to build the RJ45-to-DB9F
converter that applies to your server model number.
Table 1-3 Computer pin-outs or HP Integrity rx5670 servers
DB9 Female Pin
Wire Color
RJ45 Pin
1
Blue
1
3
Orange
2
2
Black
3
4
Red
4
5
Green
5
6
Yellow
6
7
Brown
7
8
Gray (White)
8
Table 1-4 Computer pin-outs for HP Integrity rx7620 and rx8620 servers
DB9 Female Pin
Wire Color
RJ45 Pin
4
Blue
1
8
Orange
2
5
Black
3
3
Red
4
2
Green
5
NC
Yellow
6
7
Brown
7
6
Gray (White)
8
Table 1-5 Computer pin-outs for HP Integrity Superdome/sx1000 servers
DB9 Female Pin
Wire Color
RJ45 Pin
7
Blue
1
5
Orange
2
NC
Black
3
Building a converter for your cable
15