HP Kayak XU 03xx HP Kayak PC Workstations, HP MaxiLife Hardware Monitoring - Page 14
Typical Diag Error, Messages
![]() |
View all HP Kayak XU 03xx manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
MaxiLife Hardware Monitoring Chip MaxiLife Test Sequence and Error Messages Typical Diag Error Messages When the Processor and VRM are correctly installed, the "smiling icon" is shown on the LCD status panel. Processor VRM If the Processor has only been partly inserted in the processor slot (opposite side to the VRM), then the displayed Processor VRM message will indicate a CPU socket error. If the Processor has only been partly inserted in the processor slot (closest side to the VRM), then the Processor VRM displayed message will indicate a Power CPU 1 error. The Processor has not been inserted Processor correctly in the processor slot. The displayed message will indicate a BIOS VRM error. The Processor has been correctly installed in the processor slot. However, the VRM is not installed. The displayed message will indicate a Power CPU 1 error. Processor There is no installed Processor. However, the VRM is correctly installed. The displayed message will VRM indicate a Power error. If one of the following fatal malfunctions occur, the displayed message will indicate a BIOS error: The BIOS no longer works. There is no Flash. HP KAYAK XA-s Error! CPU Socket Error! Power CPU 1 Error! BIOS Error! Power CPU 1 Error! Power supply Error! BIOS 14