HP LH4r hp lp 1000r and ds2100 config guide — for Microsoft Windo
HP LH4r - NetServer - 256 MB RAM Manual
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP LH4r manual content summary:
- HP LH4r | hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 1
Server Cluster Configuration Guide Introduction This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of two HP Netserver LP 1000r servers and one or two HP Surestore Disk Storage 2100 disk drive enclosure(s), with Microsoft® Cluster Server software - HP LH4r | hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 2
supplies I/O slots Default boot order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack Power distribution Layout Specification 256 MB, minimum. Must be HP. One PCI slot 1 IDE CD-ROM, FDD, embedded - HP LH4r | hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 3
Server I/O card slot Network interfaces Boot device Specification PCI slot 1, NetRAID-2M shared storage controller Embedded NICs for both intra-cluster (heartbeat) and client LANs Embedded SCSI Intra-Cluster (Heartbeat) LAN Configuration Parameter Network Connection NIC Quantity Specification HP - HP LH4r | hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 4
NIC Quantity Model Driver Specification Any LAN One Embedded NIC - LAN B Hptxnt5.sys, version 4.02.27, or later (driver obtained from Navigator CD-ROM L.20.00, or later) Special Notes and Warnings Disk Drive LEDs There is no hardware support in the DS2100 for disk drive failure detection or - HP LH4r | hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 5
LP1KR2K2M21 Jumpers J2 and J3 are shown in the box below. The second row of three pins is J3, the termination jumper. 1 23 J2 J3 Cover pins 2 and 3 of J3 to disable termination Setting Jumper J3 on the NetRAID-2M Controller to Disable Termination 11/15/01 5 - HP LH4r | hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 6
and 14. Setting B or C is supported. × LAN A Heartbeat Connection -crossover cable or equivalent LAN B - Client LAN SCSI Switch A B C × LAN A Heartbeat Connection -crossover cable or equivalent LAN B - Client LAN connect to NetRAID-2M channel 0 only! HP Netserver LP 1000r Cluster using one - HP LH4r | hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 7
13, and 15. × LAN A LAN B Heartbeat - Client LAN Connection -crossover cable or equivalent SCSI Switch A B C SCSI Switch A B C × LAN A LAN B Heartbeat - Client LAN Connection -crossover cable or equivalent connect to NetRAID-2M channel 0 only! HP Netserver LP 1000r Cluster using - HP LH4r | hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 8
LP1KR2K2M21 Power Cabling to Separate Power Circuits 11/15/01 8 - HP LH4r | hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 9
Versions 15 November 2001 7 November 2001 2 October 2001 Corrected part number for daisy-chaining DS2100 enclosures. Added support for 1.26 GHz models. Initial release LP1KR2K2M21 © Copyright 2001, Hewlett-Packard Company 11/15/01 9
11/15/01
1
HP Netserver LP 1000r with
NetRAID-2M (HP Surestore DS2100)
Windows
°
2000 Advanced Server
Cluster Configuration Guide
Introduction
This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of
two HP Netserver LP 1000r servers and one or two HP Surestore Disk Storage 2100 disk drive enclosure(s),
with Microsoft
Cluster Server software.
These configurations provide high server cluster availability and
minimize single points of failure (SPOFs).
A configuration certified and supported by both Hewlett-Packard
and Microsoft
is included, but any cluster configuration that conforms to the guidelines of this document
will be supported by Hewlett-Packard.
Deviations from the supported configurations can result in an
inoperative cluster, an operating cluster with degraded performance, or hidden SPOFs.
Therefore, deviations
are not supported.
For revision/update information on this document, refer to
Versions
on page 9.
Cluster Configuration Elements
This section identifies the hardware components, system software, network interfaces, and power distribution
arrangement required to build an operational server cluster supported by Hewlett-Packard.
The various
server cluster elements are listed below, and their associated configuration data is detailed in separate tables
and illustrations that follow.
•
Server configuration
•
Shared storage configuration
•
Microsoft
and HP certified server configuration
•
Intra-cluster (heartbeat) LAN configuration
•
Client LAN configuration
•
SCSI cabling and power distribution configuration
•
Special notes and warnings
Server Configuration
Parameter
Specification
Server
Type
HP Netserver LP 1000r
Number of nodes
Two
Each node must be the same server type, but nodes may differ in their CPU clock
speeds and cache sizes, and amounts of main memory.
Clock speed
1.26 GHz
This certification covers any CPU speed within 500 MHz of the certified rate.
Number of CPUs
Two
BIOS
For CPU clock speeds up to 1 GHz, version range 4.06.12 RA to 4.06.19 RA
For CPU clock speeds of 1.26 GHz, version 4.06.03 RO or later
CPU cache
Any size