HP LH4r hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 2
Local Storage, System software, Power distribution, Controller
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
LP1KR2K2M21 Server Configuration Parameter RAM Number of power supplies I/O slots Default boot order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack Power distribution Layout Specification 256 MB, minimum. Must be HP. One PCI slot 1 IDE CD-ROM, FDD, embedded SCSI, PCI slot 1 Embedded SCSI For embedded SCSI, sym_u3.sys, version 5.07.00, or later (driver obtained from Navigator CD-ROM, version L.20.00, or later) Server internal drive bays, or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications, and any SCSI bus speed Any Version M.04.00, or later Microsoft Windows® 2000 Advanced Server Latest service pack version Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 8. Shared Storage Configuration Parameter Controller Model Number of controllers BIOS Firmware Driver NetRAID Assistant SCSI ID Channels RAID levels Logical disks Specification HP NetRAID-2M Controller, Model P3411A, or P3475A One Disabled Version H.01.08 (firmware obtained from Navigator CD-ROM, version M.04.00) Mraid2k.sys, version 5.20 (driver obtained from Navigator CD-ROM, version M.04.00) Version B.01.04 (software obtained from Navigator CD-ROM, version M.04.00) 6, 7 Only a channel 0 connection is supported. Use of channel 1 can cause cluster failure. 1, 5, 10, 50 One per RAID array Eight, maximum, per cluster 11/15/01 2