HP LH4r hp lp 1000r and ds2100 config guide — for Microsoft Windo - Page 2

Local Storage, System software, Power distribution, Controller

Page 2 highlights

LP1KR2K2M21 Server Configuration Parameter RAM Number of power supplies I/O slots Default boot order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack Power distribution Layout Specification 256 MB, minimum. Must be HP. One PCI slot 1 IDE CD-ROM, FDD, embedded SCSI, PCI slot 1 Embedded SCSI For embedded SCSI, sym_u3.sys, version 5.07.00, or later (driver obtained from Navigator CD-ROM, version L.20.00, or later) Server internal drive bays, or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications, and any SCSI bus speed Any Version M.04.00, or later Microsoft Windows® 2000 Advanced Server Latest service pack version Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 8. Shared Storage Configuration Parameter Controller Model Number of controllers BIOS Firmware Driver NetRAID Assistant SCSI ID Channels RAID levels Logical disks Specification HP NetRAID-2M Controller, Model P3411A, or P3475A One Disabled Version H.01.08 (firmware obtained from Navigator CD-ROM, version M.04.00) Mraid2k.sys, version 5.20 (driver obtained from Navigator CD-ROM, version M.04.00) Version B.01.04 (software obtained from Navigator CD-ROM, version M.04.00) 6, 7 Only a channel 0 connection is supported. Use of channel 1 can cause cluster failure. 1, 5, 10, 50 One per RAID array Eight, maximum, per cluster 11/15/01 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

LP1KR2K2M21
11/15/01
2
Server Configuration
Parameter
Specification
RAM
256 MB, minimum.
Must be HP.
Number of power
supplies
One
I/O slots
PCI slot 1
Default boot order
IDE CD-ROM, FDD, embedded SCSI, PCI slot 1
Local Storage
Controller
Embedded SCSI
Driver
For embedded SCSI, sym_u3.sys, version 5.07.00, or later
(driver obtained from Navigator CD-ROM, version L.20.00, or later)
Physical drive location
Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs
Any
System software
Navigator CD-ROM
Version M.04.00, or later
Operating system
Service pack
Microsoft Windows
2000 Advanced Server
Latest service pack version
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page 8.
Shared Storage Configuration
Parameter
Specification
Controller
Model
HP NetRAID-2M Controller, Model P3411A, or P3475A
Number of controllers
One
BIOS
Disabled
Firmware
Version H.01.08
(firmware obtained from Navigator CD-ROM, version M.04.00)
Driver
Mraid2k.sys, version 5.20
(driver obtained from Navigator CD-ROM, version M.04.00)
NetRAID Assistant
Version B.01.04
(software obtained from Navigator CD-ROM, version M.04.00)
SCSI ID
6, 7
Channels
Only a channel 0 connection is supported.
Use of channel 1 can cause cluster failure.
RAID levels
1, 5, 10, 50
Logical disks
One per RAID array
Eight, maximum, per cluster