HP LH4r hp lp 1000r netraid-2m config guide — for Microsoft Windo - Page 3

Cables, Power distribution, Server, Network

Page 3 highlights

LP1000R2K2M Shared Storage Configuration Parameter Model Status SCSI ID Disk SCSI IDs Cables SCSI Power distribution Layout Specification Rack Storage/12 D5989C, containing two D6025C SCSI controller cards 5 (fixed) 0-3, 8-15 (fixed) Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 5. Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Microsoft® and HP Certified Server Configuration Parameter Server I/O card slot Network interfaces Boot device Specification PCI slot 1, NetRAID-2M shared storage controller Embedded NICs for both intra-cluster (heartbeat) and client LANs Embedded SCSI Intra-Cluster (Heartbeat) LAN Configuration Parameter Network Connection NIC Quantity Model Driver Specification HP D5954A crossover cable, or equivalent. The intra-cluster LAN may only be used for cluster node communication. It may not be used for client communication. One Embedded NIC- LAN A Hptxnt5.sys, version 4.02.27, or later (driver obtained from Navigator CD-ROM L.20.00, or later) 11/7/01 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

LP1000R2K2M
11/7/01
3
Shared Storage Configuration
Parameter
Specification
Model
Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0–3, 8–15 (fixed)
Cables
SCSI
Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See
SCSI cabling diagram
on page 5.
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page 6.
Microsoft
°
and HP Certified Server Configuration
Parameter
Specification
Server
I/O card slot
PCI slot 1, NetRAID-2M shared storage controller
Network interfaces
Embedded NICs for both intra-cluster (heartbeat) and client LANs
Boot device
Embedded SCSI
Intra-Cluster (Heartbeat) LAN Configuration
Parameter
Specification
Network
Connection
HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication.
It may
not be used for client communication.
NIC
Quantity
One
Model
Embedded NIC- LAN A
Driver
Hptxnt5.sys, version 4.02.27, or later
(driver obtained from Navigator CD-ROM L.20.00, or later)